Pellet Supply From The Pellet Silo To The Boiler - Viessmann VIESMANN VITOLIGNO 300-H Technical Manual

Boiler for automatic charging with pellets and woodchips
Table of Contents

Advertisement

Fuel discharge

Pellet supply from the pellet silo to the boiler

Vitoligno 300-H: Pellet supply by vacuum system (vacuum sys-
tem + silo)
Can be used if the pellet silo is not immediately adjacent to the instal-
lation room. Pellets can be transported up to a distance of 15 m and
to a height differential of 5 m.
A
A Pellet silo
B Return air connector
C Fill connector
5
D Pressure hose
E Suction hose
VIESMANN
38
(cont.)
B C D E F
K
H
G
F External suction turbine
G Vitoligno 300-H
H Suction hose
K Pressure hose
VITOLIGNO 300-H