Download Print this page

3M 9928 Datasheet page 2

Premium welding fume respirator

Advertisement

9928 Respirator
Fitting Instructions
1. Thread top elastic strap through
top buckles. Repeat for bottom strap
and buckles. Place the bottom elastic
strap around the head just below the
ears. Untwist the strap.
3. Adjust tension by pulling tabs of
each strap, as shown.
5. Strap tension may be decreased
without removing respirator from the
head by pushing out on the back of
the buckles. If you cannot achieve a
proper fit do not enter contaminated
area. See your supervisor.
Note: do not use with beards or
other facial hair that may inhibit
contact between the face and the
edge of the respirator.
Occupational Health Group
3M United Kingdom PLC
3M House, PO Box 1,
Market Place, Bracknell,
Berkshire RG12 1JU
Tel: Bracknell (01344) 858000.
2. Place the top elastic strap around
the head, above the ears. Untwist the
strap.
4. Using both hands, mould metal
nosepiece comfortably to shape of
nose.
6. The seal of respirator on the face
should be fit-checked prior to
wearing in the work area.
a) Cover the front of the respirator
with both hands, being careful not to
disturb the position of respirator.
b) Inhale sharply. A negative
pressure should be felt inside
respirator. If any leakage is detected,
adjust position of respirator and/or
tension of strap. Retest the seal.
Repeat the procedure until the
respirator is sealed properly.
3M Ireland
3M House, Adelphi Centre, Upper Georges St.
Dun Laoghaire
Co. Dublin, Ireland
Tel: 01 2803555
Warnings:
• As with the use of any respiratory device, the wearer must
first be trained in the proper use of the product.
• This product does not protect the wearer against gases
vapours, solvents from paint spray operations or atmospheres
containing less than 19.5% oxygen.
• 3M suggests the 9928 respirator for use up to 10 times the
Occupational Exposure Limit (OEL) of Ozone, and relief from
nuisance levels of organic vapours (i.e. levels below the OEL).
• Use only in adequately ventilated areas containing sufficient
oxygen to support life.
• Do not use when concentrations of contaminants are
immediately dangerous to life or health.
• Leave the area immediately if:
* breathing becomes difficult
* dizziness or other distress occurs
• Discard and replace respirator if it becomes damaged,
breathing resistance becomes excessive, or at the end of one
shift.
• Never alter or modify this device.
Respiratory protection is only effective if it is correctly
selected, fitted and worn throughout the time when the wearer
is exposed to hazards.
3M offers advice on the selection of products and training in
the correct fitting and usage.
For more information on 3M products and services please call
the 3M Health & Safety Helpline on 0870 60 800 60.
For callers within the Republic of Ireland: 1 800 320 500.

Advertisement