Installation
After unpacking the unit, inspect it for damage. If damage is discovered, file a claim with the
carrier, then contact ADTRAN. Refer to Warranty and Customer Service.
Shipping Contents
The contents include the following items:
• Total Reach DDS‐DP
• Total Access 1500 Total Reach DDS‐DP Job Aid (P/N 61180105L1‐22)
Instructions for Installing the Module
The TR DDS‐DP plugs directly into a Total Access 1500 shelf. No special wiring is required.
The 2‐wire loop uses the T/R (Tip and Ring) pair, pins 15 and 35, of the Total Access 1500
backplane.
Remote Unit Span Power
The TR DDS‐DP span powers the remote unit by providing ‐130 VDC measured from Tip to
Ring. Voltage measured from Tip to GND should be ‐130 VDC or less depending on voltmeter
impedance. Voltage from Ring to GND should indicate approximately 0 V.
Front Panel LEDs
The TR DDS‐DP provides front panel LEDs to display status information. The TR DDS‐DP
LEDs and status descriptions are shown in Table 4.
LED
STATUS
REM
61180105L1-5C
Table 4. Front Panel LEDs
Condition
Off
Green
2
Yellow Flashing
Yellow
Red
2
Flashing Red
Off
Green
2
Flashing Green
Description
No power or malfunction
Normal synchronized operating condition
Loopback active at remote unit
Loopback active at DDS‐DP
Indicates one of the three conditions:
1. Loss of sealing current
2. Loss of, or no synchronization
3. Poor signal quality when QM enabled (SW1‐5 ON)
CRC errors near or far
No power or malfunction
Remote provisioning in effect
DS‐6 control link established
Installation