Emerson XM670 Installation And Operation Manual page 50

Controllers for multiplexed cabinets
Table of Contents

Advertisement

ASr
1.0
PbA
5.0
AMi
0
AMA
100
AMt
200
rAL
P1
ALC
Ab
ALU
10
ALL
-30
AHy
1.0
ALd
15
dLU
150
dLL
-55
dAH
1.0
ddA
15
FLU
150
FLL
-55
FAH
1.0
FAd
15
dAo
1.3
EdA
30
dot
15
Sti
nu
Std
3
oA6
AUS
oA7
ALr
CoM
Cur
AOP
cL
iAU
n
Table 23-1 - Default Setting Values (Continued)
44 • XM679K I&O Manual
Differential for fan / offset for anti sweat
Pr2
heater
Pr2
Proportional band for modulating output
Pr2
Minimum output for modulating output
Pr2
Maximum output for modulating output
Pr2
Time with fan at maximum speed
Pr1
Probe for temperature alarm
Pr1
Temperature alarm configuration
Pr1
High temperature alarm setting
Pr1
Low temperature alarm setting
Pr1
Differential for temperature alarm
Pr1
Temperature alarm delay
High temperature alarm setting 
Pr2
(defrost probe)
Low temperature alarm setting 
Pr2
(defrost probe)
Differential for temperature alarm
Pr2
(defrost probe)
Pr2
Temperature alarm delay (defrost probe)
High temperature alarm setting 
Pr2
(fan probe)
Low temperature alarm setting 
Pr2
(fan probe)
Differential for temperature alarm 
Pr2
(fan probe)
Pr2
Temperature alarm delay (fan probe)
Pr1
Delay of temperature alarm at start-up
Pr1
Alarm delay at the end of defrost
Temperature alarm exclusion after door
Pr1
open
Pr2
Stop regulation interval
Pr2
Stop duration
Pr2
Sixth relay output configuration
Modulating output configuration 
Pr2
(if CoM=oA7)
Pr2
Modulating output configuration
Pr1
Alarm relay polarity
Auxiliary output independent from ON/
Pr1
OFF state
ALARM
nP(0) - P1(1) - P2(2) - P3(3) - P4(4) -
[0.0°C to 50.0°C or ALL to 150.0°C]
[0.0°C to 50.0°C or -55.0°C to ALU]
[0.0°C to 50.0°C or dLL to 150.0°C]
[0.0°C to 50.0°C or FLL to 150.0°C]
[0.0°C to 50.0°C or -55.0°C to FLU]
CUr(0) - tEn(1) - PM5(2) - PM6(3) -
[-45°F to 45°F]
[-25.5°C to 25.5°C]
[1°F to 45°F]
[0.1°C to 25.5°C]
0 to AMA
AMi to 100
0 to 255 s
P5(5) - tEr(6)
rE(0) - Ab(1)
[0°F to 90°F or ALL to 302°F]
[0°F to 90°F or -67°F to ALU°F]
[1°F to 45°F]
[0.1°C to 25.5°C]
0 to 255 (min.)
[0°F to 90°F or dLL to 302°F]
[0°F to 90°F or -67°F to dLU°F]
[0.0°C to 50.0°C or -55.0°C to dLU]
[1°F to 45°F]
[0.1°C to 25.5°C]
0 to 255 (min.)
[0°F to 90°F or FLL to 302°F]
[0°F to 90°F or -67°F to FLU°F]
[1°F to 45°F]
[0.1°C to 25.5°C]
0 to 255 (min.)
0 to 24.0(144)(hours.10min)
0 to 255 min
0 to 255 min
"nu"(0) to 24.0(144)(hour.10min)
1 to 255 min
CPr(0) - dEF(1) - FAn(2) - ALr(3) -
LiG(4) - AUS(5) - db(6) - OnF(7)
CPr(0) - dEF(1) - FAn(2) - ALr(3) -
LiG(4) - AUS(5) - db(6) - OnF(7)
oA7(4)
OP(0) - CL(1)
n(0) – Y(1)
026-1218 Rev 4