Setting the Date and Time
1. Select the "Others" page of the menu.
2. Enter year, month, day and time data into the "Clock"
area.
3. Click "Set".
4. Click "Refresh" several times and check that the "Sec"
value increments.
BDX-N1000
Setting the PCR Dejitter
n
To use the PCR dejitter function, the following conditions
must be satisfied.
. Use the PCR dejitter function in a network in which all
devices are synchronized.
. Set "ATM PHY Tx CK" of the "Hardware Setting" area
to the "Recovered" position. (The "ATM PHY Tx CK"
is automatically set to "Recovered" when "PCR Dejitter"
is turned on.)
. Use the PCR dejitter function with the Tx and Rx in
which their PCR dejitter functions are set to On.
1. Select the "Others" page of the menu.
2. Turn on "PCR Dejitter" in the "Hardware Setting"
area.
3. Click "Apply".
1-6. How to Use the Controller Software
1-11 (E)