How To Open The Tray When Power Switch Turn Off; Main Board Service Position - Sony HBD-TZ140 Service Manual

Table of Contents

Advertisement

HBD-TZ140

HOW TO OPEN THE TRAY WHEN POWER SWITCH TURN OFF

1 Remove the sheet.
– Bottom view –

MAIN BOARD SERVICE POSITION

Connect the MAIN board (CN500) and the POWER board (CN901) with the jig cable.
Jig cable:
Part No.
Description
A-1866-921-A
TZ140/145 SERVICE JIG ASSY
6
2 Insert the tweezers etc. in the hole of the
chassis, and push the lever in the direction
of the arrow.
3 Pull out the disc tray.
POWER board
4 Paste the sheet again.
MAIN board
MAIN board
(CN500)
TZ140/145 service jig assy
POWER board
(CN901)

Hide quick links: