I5
FM Intrinsic Safety (IS)
Certificate: 3046325
Standards: FM Class 3600 - 2011, FM Class 3610 - 2010, FM Class 3810 - 2005,
ANSI/ISA 60079-0 - 2009, ANSI/ISA 60079-11 - 2009,
NEMA 250 - 2003, ANSI/IEC 60529
Markings: IS CL I, DIV 1, GP A, B, C, D T4;
CL 1, Zone 0 AEx ia IIC T4;
T4(-40 °C ≤ T
when installed per Rosemount drawing 03031-1062;
Type 4X/IP66/IP68
Special Conditions for Safe Use (X):
1. The Model 3051 Wireless pressure Transmitter shall only be used with the
701PGNKF Rosemount SmartPower
2. The in-line pressure sensor may contain more than 10% aluminum and is
considered a potential risk of ignition by impact or friction. Care must be taken
into account during installation and used to prevent impact and friction.
3. The surface resistivity of the transmitter housing is greater than 1GΩ. To avoid
electrostatic charge build-up, it must not be rubbed or cleaned with solvents
or a dry cloth.
Canada
I6
CSA Intrinsically Safe
Certificate: 2526009
Standards: CAN/CSA C22.2 No. 0-M91, CAN/CSA C22.2 No. 94-M91,
CSA Std C22.2 No. 142-M1987, CSA Std C22.2 No. 157-92,
CSA Std C22.2 No. 60529:05
Markings: Intrinsically Safe for Class I, Division 1, Groups A, B, C, D, T4
when installed per Rosemount drawing 03031-1063;
Type 4X/IP66/IP68
Europe
I1
ATEX Intrinsic Safety
Certificate: Baseefa12ATEX0228X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
Markings:
IP66/IP68
Special Conditions for Safe Use (X):
1. The plastic enclosure may constitute a potential electrostatic ignition risk and
must not be rubbed or cleaned with a dry cloth.
2. The Model 701PGNKF Power Module may be replaced in a hazardous area. The
power module has a surface resistivity greater than 1GΩ and must be properly
installed in the wireless device enclosure. Care must be taken during
transportation to and from the point of installation to prevent electrostatic
charge build-up.
≤ +70 °C)
a
II 1 G Ex ia IIC T4 Ga, T4(-40 °C ≤ T
Battery Pack.