Install condensate line

Prepare condensate fittings
1. Remove PVC fittings and gasket from the accessories bag.
2. Deburr and chamfer outside and inside of ½" PVC nipple to ensure
even cement distribution when joining.
3. Clean nipple ends and all fittings. Dry thoroughly.
4. For each joint in the condensate line, apply the following.
Assemble parts ONLY in the order given (See Figure 58).
a. Apply primer liberally to both joint surfaces — pipe end and
fitting socket.
b. While primer is still damp, lightly apply approved cement to
both surfaces in a uniform coating.
c. Apply a second coat of cement to both surfaces. Avoid using
too much cement on sockets to prevent cement buildup inside.
d. With cement still wet, insert pipe into fitting, twisting ¼ turn.
Make sure pipe is fully inserted.
e. Wipe excess cement from joint. Check joint to be sure a smooth
bead of cement shows around the entire joint.
5. Assemble the ½" PVC nipple to the PVC reducing elbow as shown.
6. Allow joint to dry completely.
7. Then slide gasket over nipple as shown in Figure 59.
8. Slide nipple through jacket condensate line hole to position as
shown in Figure 59.
9. Cement the ½" tee to the protruding ½" nipple. Be sure both
nipple and reducing elbow finish upright.
Firmly press the reducing elbow and the tee together
while the cement sets to ensure the gasket is securely
compressed. The gasket ensures the jacket enclosure is
airtight at this location.
Connect condensate trap line and
fittings
1. Remove condensate trap line from bag.
2. Connecting condensate line assembly — Figure 60:
a. Place a hose clamp over the end of the condensate line.
b. Then slide the end of the trap line over the heat exchanger
condensate connection.
c. Tighten the hose clamp to secure the trap line.
d. See "Fill Condensate trap with water" on page 88 for proper
instructions on priming the condensate trap, if applicable at
the time.
e. Place a hose clamp over the other end of the condensate trap
line.
f. Slide the trap line over the reducing elbow and secure with
the hose clamp.
Nothing is to be added to top of this tee, Figure 59
Part number 550-100-131/0120
-
fired water boiler
— 220/299/300/399 Boiler Manual
Figure 58
Figure 59
Figure 60
.
Condensate trap assembly
Condensate trap assembled into jacket
Condensate drain line connections