Summary of Contents for Weil-McLain Evergreen Pro 220
Page 1
User’s CONDENSING GAS BOILER Information Manual 220/299/300/399 If the information in this manual is not followed exactly, a fi re or explosion may result, causing property damage, personal injury or loss of life. Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. —...
— ’ Manual CONDENSING GAS BOILER NFORMATION Please read this page fi rst To . . . Read and use . . . Page Evergreen Boiler components Locate boiler Pressure/temperature Pressure/temperature See illustration at right components gauge gauge Learn Control display Control display See Hazard Defi...
— ’ Manual CONDENSING GAS BOILER NFORMATION STOP!! — Read before proceeding Have this boiler serviced/ • Should overheating of boiler occur or gas sup- inspected by a qualified ply fail to shut off, DO NOT turn off or disconnect service technician, at least annually.
— ’ Manual CONDENSING GAS BOILER NFORMATION Prevent combustion air contamination Air contamination Combustion air contamination: Ensure that the combustion air will not contain any of Common household and hobby products often contain the contaminants in Figure 1 fl uorine or chlorine compounds. When these chemicals pass through the boiler, they can form strong acids in Combustion air supply openings or intake terminations the vent system or boiler.
— ’ Manual CONDENSING GAS BOILER NFORMATION Annual startup and general maintenance Figure 2 Service and maintenance schedules OWNER MAINTENANCE (see the following pages for instructions) Contact your boiler service technician to inspect, service and start up your boiler. You must have an annual start-up performed by BEGINNING OF SEASON a qualifi...
— ’ Manual CONDENSING GAS BOILER NFORMATION User maintenance procedures The boiler should be inspected and started annually, at the beginning of the heat- Boiler must ing season, only by a qualifi ed service technician. In addition, the maintenance and care of the boiler designated on page 5 and explained on the following pages be serviced and must be performed to assure maximum boiler effi...
Page 7
1. Observe the date and time shown on page and clean or replace the condensate drain line. 11 (the Weil-McLain logo on the control 4. To fi ll the condensate trap, if necessary, tempo- display).
Page 8
— ’ Manual CONDENSING GAS BOILER NFORMATION User maintenance procedures (continued) Check boiler piping 3. Lift the relief valve top lever slightly, al- EVERY lowing water to relieve through the valve 1. Check all gas lines and smell for gas and discharge piping.
Page 9
— ’ Manual CONDENSING GAS BOILER NFORMATION OPERATING INSTRUCTIONS Figure 5 Operating instructions (see page 2 for location of manual gas valve) Part number 550-100-213/1220...
Page 10
— ’ Manual CONDENSING GAS BOILER NFORMATION The Evergreen control display Figure 6 Evergreen boiler control display states Part number 550-100-213/1220...
Page 11
— ’ Manual CONDENSING GAS BOILER NFORMATION The Evergreen control display (continued) Figure 7 boiler control display USER Menu — (set date and time, reset faults). Evergreen BOILER STATUS screen Date and time 1. Set month, date, year, hour and minutes. 2.
Page 12
— ’ Manual CONDENSING GAS BOILER NFORMATION Part number 550-142-123/0513...