11. Safety devices

Type of
protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Terminal protection
protection
program
Terminal protection
Compressor
program
protection
(Discharge temp.)
Protection form
Activate
Reset
Activate
Reset
- 54 -
Model
AOYG18LBCB
250 V, 25 A
250 V, 5 A
250 V, 3.15 A
125±10 °C
Fan motor stop
120±10 °C
Fan motor restart
115 °C
Compressor stop
After 3 minutes
Compressor restart
AOYG24LBCB
250 V, 25 A
250 V, 5 A
250 V, 3.15 A
125±10 °C
Fan motor stop
120±10 °C
Fan motor restart
110 °C
Compressor stop
After 3 minutes
Compressor restart