Kohler Eir Comfort Height K-77795-0 Installation Manual page 4

Intelligent toilet
Table of Contents

Advertisement

Available languages

Available languages

3" (76 mm) –
6" (152 mm)
1. Roughing-In - Plug-In
WARNING: Risk of electrical shock. For plug-in installations/wall-mounted electrical supply:
Connect only to a dedicated circuit protected by a Ground-Fault Circuit-Interrupter (GFCI)*, which
protects against line-to-ground shock hazard. Use a 120 V, 15A, 60 Hz service.
CAUTION: Risk of hazardous gases. If a new toilet is not installed immediately, temporarily place
a rag in the floor flange opening.
IMPORTANT! Do not install any items behind the toilet that will interfere with the cover when it is
raised. All decorative items should be at least 42" (1067 mm) high to allow clearance for the cover.
*Outside North America, this device may be known as a Residual Current Device (RCD).
For hardwired installations, see the "Roughing-In, Hardwired" section.
Make sure that the supply stop and electrical outlet are located within the supplied dimensions.
Install the electrical outlet at the location shown.
1295780-2-A
10" (254 mm) –
12" (305 mm)
10" (254 mm) –
12" (305 mm)
Supply Stop
Location
12"
(305 mm)
5" (127 mm) –
7" (178 mm)
Floor Flange
Location
Centerline
4
Kohler Co.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents