Technical specifications
8.1
Applicability of technical specifications
Note
The following technical specifications only apply under the following conditions:
• The device is in good working order.
• The fan cover and filter pad are installed.
• The device is closed.
• The connected I/O devices meet the requirements for the respective area of application
(interference emission according to EN 61000-6-3 / IEC 61000-6-3, immunity to
interference according to EN 61000-6-2 / IEC 61000-6-2).
8.2
General technical specifications
See the note in "Applicability of technical specifications (Page 69)".
Article number
Dimensions
Weight
Power Supply
Power consumption
Current output (DC)
Noise emission
Degree of protection
Safety
Protection class
Degree of pollution
SIMATIC IPC347G
Operating Instructions, 10/2020, A5E50059993-AA
6AG4012-2...-.... (for details, refer to the ordering documentation)
481 × 176 × 509 (W × H × D in mm)
Detailed dimensional specifications can be found in "Dimension drawings (Page 78)".
13.3 up to 17 kg; depending on the equipment
•
Input Rating:100 VAC to 240 VAC ; 6 to 3A; 60 to 50Hz
•
Rated output power: 350W (+3.3V & +5V≤105W)
•
Full load (100%, 350 W) at 82% efficiency
•
Typical load (50%, 175 W) at 85% efficiency
•
Light load (20%, 70 W) at 82% efficiency
•
+5 V/16 A, +3.3 V/19 A
105 W permitted in total
•
+12 V1/17 A, +12 V2/17 A
•
-12 V/0.3 A, +5 V
/2.5 A
aux
The total sum of all voltages is max. 210 W
< 55 dB (A)
•
IP 20 on the rear according to IEC 60529
Protection class I compliant with IEC 61140
Device is designed for environments with pollution degree 2
8
69