Technical Specifications; Applicability Of Technical Specifications; General Technical Specifications - Siemens SIMATIC IPC347G Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC347G:
Table of Contents

Advertisement

Technical specifications

8.1

Applicability of technical specifications

Note
The following technical specifications only apply under the following conditions:
• The device is in good working order.
• The fan cover and filter pad are installed.
• The device is closed.
• The connected I/O devices meet the requirements for the respective area of application
(interference emission according to EN 61000-6-3 / IEC 61000-6-3, immunity to
interference according to EN 61000-6-2 / IEC 61000-6-2).
8.2

General technical specifications

See the note in "Applicability of technical specifications (Page 69)".
Article number
Dimensions
Weight
Power Supply
Power consumption
Current output (DC)
Noise emission
Degree of protection
Safety
Protection class
Degree of pollution
SIMATIC IPC347G
Operating Instructions, 10/2020, A5E50059993-AA
6AG4012-2...-.... (for details, refer to the ordering documentation)
481 × 176 × 509 (W × H × D in mm)
Detailed dimensional specifications can be found in "Dimension drawings (Page 78)".
13.3 up to 17 kg; depending on the equipment
Input Rating:100 VAC to 240 VAC ; 6 to 3A; 60 to 50Hz
Rated output power: 350W (+3.3V & +5V≤105W)
Full load (100%, 350 W) at 82% efficiency
Typical load (50%, 175 W) at 85% efficiency
Light load (20%, 70 W) at 82% efficiency
+5 V/16 A, +3.3 V/19 A
105 W permitted in total
+12 V1/17 A, +12 V2/17 A
-12 V/0.3 A, +5 V
/2.5 A
aux
The total sum of all voltages is max. 210 W
< 55 dB (A)
IP 20 on the rear according to IEC 60529
Protection class I compliant with IEC 61140
Device is designed for environments with pollution degree 2
8
69

Advertisement

Table of Contents
loading

Table of Contents