Power Supply - IBM PS/2 65 SX Hardware Maintenance Reference

Hide thumbs Also See for PS/2 65 SX:
Table of Contents

Advertisement

|3.1 Power Supply

|The power supply automatically switches to either the 100-125 Vac or the
|200-240 Vac range.
The ac input is converted to dc outputs that supply
|the system with proper operating voltages.
|When the system is powered-off for 10 seconds or more and then powered-on,
|the power supply generates a 'power good' signal that resets system logic.
|The presence of the 'power good' signal indicates that the power supply is
|operating properly and that the minimum under-voltage sense levels have
|been established.
This means that all system-board power requirements
|have been met.
+-----------------------------------------+
¦ Output
¦ Minimum Under-Voltage
¦ (Vdc)
¦ Sense Level (Vdc)
+------------+----------------------------¦
¦ + 5.0
¦ + 4.5
+------------+----------------------------¦
¦ +12.0
¦ +10.8
+------------+----------------------------¦
¦ -12.0
¦ -10.2
+------------+----------------------------¦
¦
¦
+-----------------------------------------+
|The 'power good' signal turns on the green power-good light on the front
|of the system.
If the green light is not on, the power supply is not
|functioning properly.