Advertisement

Quick Links

IBM PS/2 Model 60 HMS
FRONT
PICTURE 1
September 25, 1990
This pamphlet contains procedures for isolating problems to a FRU, a
Symptom-to-FRU Index, and a parts listing for the IBM Personal System/2
Model 60.
This pamphlet is intended to be used with the IBM Personal System/2
Hardware Maintenance Reference manual (part number 15F2190, form number
S15F-2190-00) and the IBM Personal System/2 Hardware Maintenance Service
manual (part number 15F2200, form number S15F-2200-00).
Part Number 84F9825
Form Number S15F-2194-01
FRONT - 1

Advertisement

Table of Contents
loading

Summary of Contents for IBM PS/2 60

  • Page 1 Symptom-to-FRU Index, and a parts listing for the IBM Personal System/2 Model 60. This pamphlet is intended to be used with the IBM Personal System/2 Hardware Maintenance Reference manual (part number 15F2190, form number S15F-2190-00) and the IBM Personal System/2 Hardware Maintenance Service manual (part number 15F2200, form number S15F-2200-00).
  • Page 2: Safety Information

    Such references or information must not be construed to mean that IBM intends to announce such IBM products, programming, or services in your country. Requests for technical information about IBM products should be made to your IBM Authorized Dealer or your IBM Marketing Representative.
  • Page 3: Special Notices

    Special Notices FRONT_2 Special Notices References in this publication to IBM products, programs, or services do not imply that IBM intends to make these available in all countries in which IBM operates. Any reference to an IBM product, program or service is not intended to state or imply that only IBM's product, program, or service may be used.
  • Page 4: Table Of Contents

    IBM PS/2 Model 60 HMS Table of Contents CONTENTS Table of Contents FRONT_1 Safety Information FRONT_2 Special Notices CONTENTS Table of Contents General Checkout How to Diagnose Combined FRUs How to Use Error Messages Installed Devices List Automatic Configuration Device Type...
  • Page 5: General Checkout

    IBM PS/2 Model 60 HMS General Checkout 1.0 General Checkout The advanced diagnostic tests are intended to test only IBM (*) products. Non-IBM products, prototype cards, or modified options can give false errors and invalid system responses. (*) Trademark of the International Business Machines Corporation.
  • Page 6 IBM PS/2 Model 60 HMS How to Diagnose Combined FRUs 1.1 How to Diagnose Combined FRUs If an adapter or device consists of more than one FRU, an error code may be caused by any of the FRUs. Before replacing the adapter or device, remove the FRUs, one by one, to see if the symptoms change.
  • Page 7 IBM PS/2 Model 60 HMS How to Use Error Messages 1.2 How to Use Error Messages Use the error codes displayed on the screen to diagnose failures. If more than one error code is displayed, diagnose the first error code first.
  • Page 8 IBM PS/2 Model 60 HMS How to Use Error Messages +---+ - Remove the Reference Diskette and restart the system. DID THE ERROR REMAIN? ¦ ¦ ¦ +---+ ¦ ¦012¦ ¦ +---+ ¦ If you suspect another problem, or want to run system checkout, ¦...
  • Page 9 IBM PS/2 Model 60 HMS How to Use Error Messages ¦ Reseat all adapters, drives, and modules. ¦ Check the system unit fan for proper operation. ¦ Start an error log and run the tests multiple times. ¦ +---+ ¦020¦...
  • Page 10: Installed Devices List

    IBM PS/2 Model 60 HMS Installed Devices List 2.0 Installed Devices List If an adapter or device is missing from the list, you may have one of the following conditions: Your Reference Diskette does not contain the module of code required to support that device.
  • Page 11 IBM PS/2 Model 60 HMS Automatic Configuration 2.1 Automatic Configuration Warning: A customized setup configuration (other than default settings) may exist on the system you are servicing. Running Automatic Configuration may alter those settings. Note the current configuration settings (using the View Configuration option) and verify that the settings are in place when service is complete.
  • Page 12 IBM PS/2 Model 60 HMS Device Type 2.2 Device Type Run Automatic Configuration (see "Automatic Configuration" in topic 2.1 before continuing) and determine which type of device, SCSI or non-SCSI, is missing from the Installed Devices List, in Advanced Diagnostics, then continue with the following steps.
  • Page 13 IBM PS/2 Model 60 HMS SCSI Devices 2.3 SCSI Devices The adapter supporting the missing device may be defective. If more than one SCSI adapter is installed, isolate them one at a time. Power-off the system and disconnect all internal and external cables attached to the SCSI adapter.
  • Page 14 IBM PS/2 Model 60 HMS Non-SCSI Devices 2.4 Non-SCSI Devices The missing device is defective. If that does not correct the problem, go to "Undetermined Problem" in topic 4.0. Note: If the number of diskette drives shown on the list is incorrect, an error can occur during the tests.
  • Page 15: Power-On Password

    IBM PS/2 Model 60 HMS Power-On Password 3.0 Power-On Password To service a system with an active, unknown, power-on password do one of the following, depending on which battery and speaker assembly is installed. On the type with two pins on the side of the speaker assembly, short the pins together.
  • Page 16: Undetermined Problem

    IBM PS/2 Model 60 HMS Undetermined Problem 4.0 Undetermined Problem Power-off the system. Remove or disconnect one of the following adapters or devices: Non-IBM devices Any external device (modem, printer, or mouse) Any adapter Fixed disk or diskette drive Memory module kits Math coprocessor.
  • Page 17: Power Supply Voltages / Fan

    IBM PS/2 Model 60 HMS Power Supply Voltages / Fan 5.0 Power Supply Voltages / Fan If the voltages are not correct, or if the fan is not running, replace the power supply. +------------------------------------------------------------------------+ ¦ Vdc ¦ Vdc ¦ -Lead ¦...
  • Page 18: Enable, Disable Settings

    IBM PS/2 Model 60 HMS Enable, Disable Settings 6.0 Enable, Disable Settings To verify that the "Enable" and "Disable" settings are correct, select Set and View SCSI Device Configuration from the Set Configuration menu, and determine if there are any "Presence Error Reporting" devices listed.
  • Page 19: Display Self-Test

    IBM PS/2 Model 60 HMS Display Self-Test 7.0 Display Self-Test Power-off the system unit and display. Disconnect the display signal cable. Power-on the display. Turn the contrast to its maximum position. Turn the brightness control to the center detent position.
  • Page 20: Display Adapter 8514/A

    IBM PS/2 Model 60 HMS Display Adapter 8514/A 8.0 Display Adapter 8514/A PICTURE 3 8.0 - 1...
  • Page 21: Keyboard

    IBM PS/2 Model 60 HMS Keyboard 9.0 Keyboard +---+ ¦001¦ +---+ - Power-off the system. - Disconnect the keyboard cable from the keyboard. - Power-on the system and check the keyboard cable connector for the voltages shown. All voltages are ± 5%.
  • Page 22: Printer

    IBM PS/2 Model 60 HMS Printer 10.0 Printer Make sure the printer is properly connected and powered-on. Run the printer self-test. If the printer self-test does not run correctly, the problem is in the printer. Refer to the printer service manual.
  • Page 23: Memory

    IBM PS/2 Model 60 HMS Memory 11.0 Memory Note: Power-off the system before removing or replacing parts. 00011000 indicates a system-board parity-check error. Replace the memory modules. If that does not solve the problem, replace the system board. 00011100 indicates a memory-adapter parity-check error.
  • Page 24 An "X" in an error message can be any number. Note: If you are unable to find an error message, you have an IBM device with its own service manual or a device not supported by the advanced diagnostic tests.
  • Page 25 IBM PS/2 Model 60 HMS Symptom-to-FRU Index ¦ One long and two short beeps ¦ ¦ ¦ (See "Display Self-Test" in ¦ Display Option Adapter ¦ ¦ topic 7.0 before replacing any ¦ System Board ¦ ¦ FRUs.) ¦ Power Supply ¦...
  • Page 26 IBM PS/2 Model 60 HMS Symptom-to-FRU Index ¦ (See "Keyboard" in topic 9.0 ¦ System Board ¦ ¦ before replacing any FRUs.) ¦ Keyboard ¦ ¦ ¦ Keyboard Cable ¦ ¦ ¦ ¦ +------------------------------------+-----------------------------------¦ ¦ 000304XX ¦ ¦ ¦ (See "Keyboard" in topic 9.0 ¦...
  • Page 27: Symptom-To-Fru Index

    IBM PS/2 Model 60 HMS Symptom-to-FRU Index ¦ ¦ ¦ +------------------------------------+-----------------------------------¦ ¦ 001782XX ¦ ¦ ¦ ¦ Fixed Disk Drive Adapter (ST506) ¦ ¦ ¦ System Board ¦ ¦ ¦ ¦ +------------------------------------+-----------------------------------¦ ¦ 001790XX ¦ ¦ ¦ ¦ Fixed Disk Drive C ¦...
  • Page 28 IBM PS/2 Model 60 HMS Symptom-to-FRU Index ¦ ¦ Memory Adapter/A ¦ ¦ ¦ System Board ¦ ¦ ¦ ¦ +------------------------------------+-----------------------------------¦ ¦ 008601XX, 008602XX ¦ ¦ ¦ ¦ Pointing Device ¦ ¦ ¦ ¦ +------------------------------------+-----------------------------------¦ ¦ 008603XX ¦ ¦ ¦...
  • Page 29 IBM PS/2 Model 60 HMS Symptom-to-FRU Index ¦ ¦ Fixed Disk Drive Adapter (ESDI) ¦ ¦ ¦ ¦ +------------------------------------+-----------------------------------¦ ¦ 0104XXXX ¦ ¦ ¦ (not listed above) ¦ Fixed Disk Drive C or D ¦ ¦ ¦ Fixed Disk Drive Adapter (ESDI) ¦...
  • Page 30 IBM PS/2 Model 60 HMS Symptom-to-FRU Index -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- -------------------------------------------------------------------------- 12.0 - 7...
  • Page 31: How To Use This Parts Catalog

    IBM PS/2 Model 60 HMS How To Use This Parts Catalog 13.0 How To Use This Parts Catalog INDEX REFERENCE NUMBERS: Refer to the illustrations for index reference numbers listed in the left margin of the parts listing. SIMILAR ASSEMBLIES: If two assemblies contain a majority of identical parts, they are broken down on the same list.
  • Page 32: System Overview

    IBM PS/2 Model 60 HMS System Overview 14.0 System Overview PICTURE 5 14.0 - 1...
  • Page 33: Parts

    IBM PS/2 Model 60 HMS Parts 15.0 Parts Index System Unit Exterior Handle 72X8569 Bezel/Logo (R)(Exchange Only) 72X8549 Diskette-Drive Bezel 72X8550 Base Foot 72X8565 Cover 72X8548 System Base 72X8593 6 mm Screw Flat Washer Spring Washer (Rear Foot) Detent (Front Foot)
  • Page 34 IBM PS/2 Model 60 HMS Parts 1.2MB Adapter/A 15F7996 Diskette Drive Cables (see DASD Cables) Fixed Disk Drives 44MB Fixed Disk Drive (ST506) 72X8541 70MB Fixed Disk Drive (ESDI) 72X8519 115MB Fixed Disk Drive (ESDI) 90X7392 60MB Fixed Disk Drive (SCSI)
  • Page 35 IBM PS/2 Model 60 HMS Parts 3270 Connection 74F3464 36/38 Emulation Adapter 69X6281 6157 Tape Adapter 92X1459 0-8MB Expanded Memory Adapter/A 1497253 256KB Memory Module (for 1497253) 1497256 1MB Memory Module (for 1497253) 74X8637 2-8MB 80286 Memory Expansion Option 15F8292...
  • Page 36 IBM PS/2 Model 60 HMS Parts with tilt/swivel and packaging set 07F6652 Model A01 (90/265 Vac) with tilt/swivel and packaging set 07F6651 Shipping material: 16F0188 Front cushion Rear cushion Power cable, 1.8 (6 ft), U.S. 38F3968 Alternative to part number 38F3968 above...
  • Page 37 IBM PS/2 Model 60 HMS Parts Printed in the United States of America 15.0 - 5...

Table of Contents