Unit Installation
BBU Maintenance
•
The BBU does not require routine maintenance for normal operation. The life expectancy of the BBU
is 3 to 5 years on standby when used at room temperature.
•
Excessive heat decreases battery power and life. Extreme low temperature also decreases battery
capacity. Ideal ambient temperature for battery life and capacity is 20°C.
•
Battery shelf life is extended in cooler temperatures.
•
To order replacement batteries, reference the following part number: 1975044L1 (12 VDC replacement
batteries).
ADTRAN is an environmentally friendly company. Therefore, we encourage the proper recycling and handling
of the batteries. Federal and state laws prohibit the improper disposal of all lead acid batteries. The customer is
responsible for the handling of their batteries from the day of purchase through their ultimate disposal. For more
information on battery replacement and recycling, refer to the manufacturer's documentation.
BBU Specifications
Table 8
provides BBU specifications.
Battery
Part Number:
Suppliers:
Batteries:
Voltage:
Backup Time:
Wire Gauge:
Environmental
Operating Temperatures:
Preferred:
Physical Dimensions
P/N 1175044L1:
Weight:
Installing Network Modules
The network modules are installed into the rear panel option module slot. The following table lists the
installation steps. Also, see
All unused option module slots on the front panel of the unit must remain covered with the
supplied cover plates.
38
Table 8. BBU Specifications
311212V02
YUASA and Panasonic
7 AHR per battery
-12 VDC per battery
Up to 8 hours
18 AWG
Charge: -15°C to 50°C
Discharge: -20°C to 60°C
20°C
17-inch W x 6.5-inch H x 3.5-inch D
30 lb
Figure 12 on page
39.
Copyright © 2014 ADTRAN, Inc.
NetVanta 6360 Hardware Installation Guide
617006364F1-34A