Fixing The Installation Plate; Purging The Unit - Samsung AVXWVH022EE Installation Manual

Wall-mounted type series
Hide thumbs Also See for AVXWVH022EE:
Table of Contents

Advertisement

Fixing the Installation Plate

Installation plate
Pipe hole
(Ø65mm)
(Unit : mm)
022/028/036
90
(Unit : mm)
056/071
74

Purging the Unit

8
E-
AVXWV@@_IM_E_29819-1_4.14.09.indd 8
Before fixing the installation plate to the wall or window frame, you must
determine the position of the 65mm hole through which the cable, pipe and
hose pass to connect the indoor unit to the outdoor unit.
When facing the wall, the pipe and cable can be connected from the:
1
Determine the position of the pipe and drain hose hole as seen in the picture
and drill the hole with an inner diameter of 65mm so that it slants slightly
downwards.
2
If you fix the indoor unit to a...
Wall
Window frame
3
Fix the installation plate to the wall giving attention to the weight of the
indoor unit.
45
 If you mount the plate to a concrete wall with anchor bolts, the anchor
90
bolts must not project more than 20mm.
4
Determine the positions of the wooden uprights to be attached to the
window frame.
5
Attach the wooden uprights to the window frame giving attention to the
47
weight of the indoor unit.
74
6
Attach the installation plate to the wooden uprights using tapping screws as
seen in the picture.
On delivery, the indoor unit is loaded with an inert Nitrogen gas.
All this gas must therefore be purged before connecting the assembly piping.
To purge the inert gas, proceed as follows.
1
Unscrew the caps at the end of each pipe.
Result: All inert gas escapes from the indoor unit.
Note
Right
Left
Underside (right)
Rear (right or left)
Follow step(s)...
3.
4 to 6.
 T o prevent dirt or foreign objects from getting into the pipes
during installation, do NOT remove the caps completely until you are
ready to connect the piping.
2009-4-14 10:15:30