  • Page 1 ® INSTRUCTION MANUAL 3 series Upper Arm Blood Pressure Monitor Model BP7100...
  • Page 2: Table Of Contents

    Table of Contents Introduction ....................3 Important Safety Information ................4 1. Know Your Monitor ................8 2. Preparation ..................13 3. Using the Monitor.................14 4. Error Messages and Troubleshooting..........20 5. Maintenance ..................23 6. Specifications..................25 7. FCC Statement ..................27 8. Limited Warranty..................28 9. Guidance and Manufacturer’s Declaration...........30...
  • Page 3: Introduction

    Introduction Thank you for purchasing the OMRON BP7100 Blood Pressure Monitor. This new blood pressure monitor uses the oscillometric method of blood pressure measurement. This means this monitor detects your blood movement through your brachial artery and converts the movements into a digital reading.
  • Page 4: Important Safety Information

    Important Safety Information Please read the Important Safety Information in this instruction manual before using this monitor. Please follow this instruction manual thoroughly for your safety. Please keep for future reference. For specific information about your own blood pressure, CONSULT WITH YOUR PHYSICIAN. Indicates a potentially hazardous situation which, if not Warning avoided, could result in death or serious injury.
  • Page 5 Battery Handling and Usage • Keep batteries out of the reach of infants, toddlers or children. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user Caution or patient, or cause damage to the equipment or other property.
  • Page 6 • Ensure that this monitor has acclimated to room temperature before taking a measurement. Taking a measurement after an extreme temperature change could lead to an inaccurate reading. OMRON recommends waiting for approximately 2 hours for the monitor to warm up or cool down when the...
  • Page 7 Battery Handling and Usage • DO NOT insert batteries with their polarities incorrectly aligned. • ONLY use 4 “AA” alkaline or manganese batteries with this monitor. DO NOT use other types of batteries. DO NOT use new and used batteries together. •...
  • Page 8: Know Your Monitor

    1. Know Your Monitor Contents: Monitor, arm cuff, instruction manual, quick start guide Monitor: A. Display D. Battery compartment B. START/STOP button E. Air jack C. Memory button Arm cuff: F. Arm cuff (Arm circumference 9" - 17" (22 - 42 cm)) G.
  • Page 9 Display: Memory symbol N. Irregular heartbeat symbol J. Systolic blood pressure O. Movement error symbol K. Diastolic blood pressure P. Pulse display / Memory number L. Low battery symbol Q. Deflation symbol M. Heartbeat symbol (Flashes during measurement.)
  • Page 10 1.1 Display symbols Irregular Heartbeat Symbol ( Normal Heartbeat When the monitor detects an irregular Pulse rhythm two or more times during the measurement, the irregular heartbeat Blood pressure symbol will appear on the display with Irregular Heartbeat the measurement values. An irregular Short Long heartbeat rhythm is defined as a rhythm Pulse...
  • Page 11 Movement Error Symbol ( The movement error symbol is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2 - 3 minutes. Take another measurement, remain still during measurement. Classification of BP (Blood Pressure) ACC/AHA 2017 Hypertension guidelines define categories of BP in adults as below.
  • Page 12 1.2 Blood Pressure Measurement Tips To help ensure an accurate reading, follow these directions: • Stress raises blood pressure. Avoid taking measurements during stressful times. • Measurements should be taken in a quiet place. • It is important to take measurements at the same times each day. Taking measurements in the morning and in the evening is recommended.
  • Page 13: Preparation

    2. Preparation 2.1 Battery Installation Remove the battery cover. Insert 4 “AA” batteries as indicated in the battery compartment. Replace the battery cover. Notes: • When the low battery symbol ( ) appears on the display, turn the monitor off, then replace all batteries at the same time. Long life alkaline batteries are recommended.
  • Page 14: Using The Monitor

    3. Using the Monitor 3.1 Applying the Arm Cuff Remove tight-fitting, thick clothing from your arm Caution while taking a measurement. Insert the air plug into the air jack securely. Wrap the arm cuff firmly in place around your left upper arm.
  • Page 15 • The blood pressure can differ between the right arm and the left arm, and the measured blood pressure values can be different. OMRON recommends to always use the same arm for measurement. If the values between both arms differ substantially, please check with your physician which arm to use for your measurements.
  • Page 16 3.2 How to Sit Correctly To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. Avoid bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement. • Sit in a chair with your legs uncrossed and feet flat on the floor.
  • Page 17 3.3 Taking a Measurement Notes: • To stop the measurement, press the START/STOP button once to deflate the arm cuff. • Remain still and quiet while taking a measurement. Press the START/STOP button. The arm cuff will start to inflate automatically. START INFLATING COMPLETED...
  • Page 18 Remove the arm cuff. Press the START/STOP button to turn the monitor off. The monitor automatically stores the measurement result in its memory. It will automatically turn off after 2 minutes. Note: Wait 2-3 minutes before taking another measurement. Waiting between measurements allows the arteries to return to the condition prior to taking a measurement.
  • Page 19 3.4 Using the Memory Function The monitor automatically stores the results up to 14 sets. Note: If the memory is full, the monitor will delete the oldest value. To View the Measurement Values Stored in Memory Press the button. The Memory number appears for a second before the pulse rate is displayed.
  • Page 20: Error Messages And Troubleshooting

    4. Error Messages and Troubleshooting 4.1 Error Messages Error Display Cause Solution Remove the arm cuff. Wait 2 - 3 minutes and then take another Irregular heartbeats are measurement. Repeat the steps detected. in section 3.3. If this error continues to appear, contact your physician.
  • Page 21 Error Display Cause Solution Repeat measurement. Remain still and do not talk during measurement. Refer to section 3.3. Movement during measurement If “E2” appears repeatedly, and the arm cuff has not been inflate the arm cuff manually inflated sufficiently. until it is 30 to 40 mmHg above your previous measurement result.
  • Page 22 4.2 Troubleshooting Problem Cause and Solution Replace all batteries with new ones. No power. Check the battery installation for proper placement of the battery polarities. No display appears on the monitor. Refer to section 2.1. Blood pressure varies constantly. Many factors including stress, time of day, and Measurement values appear too high or how you wrap the cuff, may affect your...
  • Page 23: Maintenance

    5. Maintenance 5.1 Maintenance To protect your monitor from damage, please follow the directions below: • Changes or modifications not approved by the manufacturer will void the user warranty. • DO NOT disassemble or attempt to repair this monitor or other components.
  • Page 24 5.3 Cleaning • Do not use any abrasive or volatile cleaners. • Use a soft dry cloth or a soft cloth moistened with neutral soap to clean your monitor and arm cuff, and then wipe them with a dry cloth. •...
  • Page 25: Specifications

    6. Specifications Model BP7100 HEM-7121-Z2 Display LCD digital display Cuff pressure range Pressure: 0 to 299 mmHg Measurement range Pressure: 20 to 280 mmHg Pulse: 40 to 180 beats / min. Pressure: ±3 mmHg Accuracy Pulse: ± 5% of display reading Inflation Fuzzy-logic controlled by electric pump Deflation...
  • Page 26 Notes: • These specifications are subject to change without notice. • This monitor is clinically investigated according to the requirements of ISO 81060-2:2013. In the clinical validation study, K5 was used on 85 subjects for determination of diastolic blood pressure. •...
  • Page 27: Fcc Statement

    Guidance and manufacturer’s declaration - electromagnetic emissions OMRON BP7100 is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON BP7100 should assure that it is used in such environment. Emissions test Compliance...
  • Page 28: Limited Warranty

    <5 % U (>95 % dip in U for 0.5 cycle 40 % U (60 % dip Voltage dips, short in U interruptions and for 5 cycles voltage variations on Not Applicable. Not Applicable. 70 % U (30 % dip power supply inputlines in U IEC 61000-4-11...
  • Page 29 Guidance and manufacturer’s declaration - electromagnetic immunity OMRON BP7100 is intended for use in the electromagnetic environment specified below. The customer or the user of this OMRON BP7100 should assure that it is used in such environment. Compli IEC 60601 test...
  • Page 30: Guidance And Manufacturer's Declaration

    OMRON BP7100 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of this OMRON BP7100 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the OMRON BP7100 as recommended below, according to the maximum output power of the communications equipment.