MCAC-VTSM-2017-01 One-way Cassette 1. Features 1.1 New panel design The new panel is equipped with digital display function, which can show temperature, warning message and check running parameters. 1.2 Compact design For capacity 1.8kW to 3.6kW, needs only 153mm space above the ceiling. And 189mm for 4.5~7.1kW models.
One-way Cassette MCAC-VTSM-2017-01 2. Specifications Model MDV-D18Q1/N1-D MDV-D22Q1/N1-D Power supply 1 phase, 220-240V, 50Hz Capacity Cooling Input Rated current 0.24 0.24 Capacity Heating Input Rated current 0.24 0.24 Model RPS12N Type Indoor fan motor Input(H/M/L) 29.5/26.7/25.0 29.5/26.7/25.0 μF Capacitor Speed (H/M/L) r/min 1180/955/710 Number of rows...
Page 6
MCAC-VTSM-2017-01 One-way Cassette Specifications Model MDV-D28Q1/N1-D MDV-D36Q1/N1-D Power supply 1 phase, 220-240V, 50Hz Capacity Cooling Input Rated current 0.25 0.25 Capacity Heating Input Rated current 0.25 0.25 Model RPS12N Type Indoor fan motor Input(H/M/L) 31.0/27.2/25.3 31.0/27.2/25.3 μF Capacitor Speed (H/M/L) r/min 1270/1050/790 Number of rows...
Page 7
One-way Cassette MCAC-VTSM-2017-01 Specifications Model MDV-D45Q1/N1-D MDV-D56Q1/N1-D MDV-D71Q1/N1-D Power supply 1 phase, 220-240V, 50Hz Capacity Cooling Input Rated current 0.27 0.32 0.36 Capacity Heating Input Rated current 0.27 0.32 0.36 Model YDK38-4 YDK43-4 Type Indoor fan motor Input(H/M/L) 39.5/33.5/25.6 41.5/36.0/28.0 56.2/40.2/28.7 μF Capacitor...
Page 9
One-way Cassette MCAC-VTSM-2017-01 MDV-D45Q1/N1-D MDV-D56Q1/N1-D MDV-D71Q1/N1-D 1350 75 30 1054 1061 1235 1235 Please use the installation paper plate to make sure the Please use the installation paper plate to make sure the position of the installation screws. positions of the installation screws. 4×Φ10 Screw fixing size:D Ceiling cutting size:C...
MCAC-VTSM-2017-01 One-way Cassette 4. Service Spaces Please avoid installing in the following places : A place with flammable gas or material. A saline place such as a seashore vicinity. A place with sulphur gas. A place with oil gas,such as kitchen. A place with high-humidity air.
Page 14
MCAC-VTSM-2017-01 One-way Cassette HP set switch ENC1 definition list Code Name Indoor Unit Fan motor Code Capacity Value Swinging motor 1800W(0.6HP) Water drainage pump 2200W(0.8HP) Water level switch 2800W(1.0HP) Electronic expansion valve 3600W(1.2HP) Indoor temp. sensor 4500W(1.5HP) Mid-pipe temp. sensor of evaporator 5600W(2.0HP) Outlet temp.
MCAC-VTSM-2017-01 One-way Cassette 10. Accessories Standard accessories Name Quantity Outline Function Indoor unit Hand to the user installation manual Installation paper plate For installing the suspender and cutting the ceiling Protection sleeve for For heat insulation of the pipe connections refrigerant inlet and outlet pipes Fastening belt For fastening...
MCAC-VTSM-2017-01 Two-way Cassette 1. Features 1.1 Lower noise level 1.2 Smoother air flow with less turbulence 1.3 Double-flow type allows effective air discharge from corner or from drop-ceiling. 1.4 Stylish design Be harmonious with any interior decoration and creates an elegant environment 1.5 Thin main body Slim body needs 300 mm space above the ceiling, reduces the suspended ceiling space.
Two-way Cassette MCAC-VTSM-2017-01 2. Specifications Model MDV-D22Q2/N1 MDV-D28Q2/N1 MDV-D36Q2/N1 Power supply 1 phase, 220-240V, 50Hz Capacity Cooling Input Rated current Capacity Heating Input Rated current Model YSK31-6-1 YSK31-6-1 YSK31-6 Type Indoor fan motor Input Capacitor Speed (H/M/L) r/min 670/550/450 670/550/450 730/590/470 Number of rows Tube pitch(a) ×...
Page 30
MCAC-VTSM-2017-01 Two-way Cassette Specifications Model MDV-D45Q2/N1 MDV-D56Q2/N1 MDV-D71Q2/N1 Power supply 220-240V-1ph-50Hz Capacity Cooling Input Rated current 0.65 0.85 Capacity Heating Input Rated current 0.65 0.85 Model YSK58-4-1 YSK58-4 YSK91-4 Type Indoor fan motor Input Capacitor Speed (H/M/L) r/min 801/645/542 910/755/642 1159/1032/795 Number of rows Tube pitch(a) ×...
Two-way Cassette MCAC-VTSM-2017-01 10. Accessories Standard accessories Name Quantity Shape Purpose Guidance of installation for indoor unit and Installation Manual for Indoor Unit must deliver to the customer Use for heat-insulating of pipe connecting Heat-insulated Pipe parts Protection Pipe Use for heat insulation of flexible pipe Matched Resistance(also Improve the stability of communication Network Matching Wiring Group)
Compact Four-way Cassette MCAC-VTSM-2017-01 1. Features (1) Low operation noise, quiet design for user comfort Streamline plate ensures quietness Creates natural and comfortable environment (2) Efficient cooling Equal, fast and wide—range cooling (3) The adoption of the most advanced 3-dimensional centrifugal fan Reduces the air resistance passing through Smooths air flow Makes air speed distribution to the heat exchange uniform...
MCAC-VTSM-2017-01 Compact Four-way Cassette 2. Specifications Model MDV-D15Q4/N1-A3 MDV-D22Q4/N1-A3 MDV-D28Q4/N1-A3 Power supply 1 phase, 220-240V, 50Hz Capacity Cooling Input Rated current 0.22 0.22 0.22 Capacity Heating Input Rated current 0.22 0.22 0.22 Model YDK15-6M Type Indoor fan motor Input Capacitor Speed (H/M/L) r/min 630/540/447...
Page 47
Compact Four-way Cassette MCAC-VTSM-2017-01 Specifications Model MDV-D36Q4/N1-A3 MDV-D45Q4/N1-A3 Power supply 1 phase, 220-240V, 50Hz Capacity Cooling Input Rated current 0.25 0.25 Capacity Heating Input Rated current 0.25 0.25 Model YDK15-6P Type Indoor fan motor Input Capacitor Speed (H/M/L) r/min 780/670/540 Number of rows Tube pitch(a) ×...
Compact Four-way Cassette MCAC-VTSM-2017-01 4. Service Spaces There is enough room for installation and maintenance. The ceiling is horizontal, and its structure can endure the weight of the indoor unit. The outlet and the inlet are not impeded, and the influence of external air is the least. The air flow can reach throughout the room.
Four-way Cassette MCAC-VTSM-2017-01 1. Features (1) Low operation noise Streamline plate ensures quietness Creates natural and comfortable environment (2) Efficient cooling——Equal, fast and wide range cooling (3) Excellent performance. Higher heat-exchanging efficiency and lower noise. The optimal evaporator & sufficient airflow volume guarantees the excellent capacity (4) The adoption of the most advanced 3-dimensional centrifugal fan Reduces the air resistance passing through Smooths the air flow...
Page 62
MCAC-VTSM-2017-01 Four-way Cassette (9) Swing angle of louver Add one more swing motor, one motor driving two louvers. Controlling the interspace of each part, minimizing the angle loss. The swing angle of the first louver are 40~42 degrees and the second louver are 37~38 degrees. New evaporator and inner configuration designed can acquire high heat-exchanger effect.
Four-way Cassette MCAC-VTSM-2017-01 4. Service Spaces There is enough room for installation and maintenance. The ceiling is horizontal, and its structure can endure the weight of the indoor unit. The outlet and the inlet are not impeded, and the influence of external air is the least. The air flow can reach throughout the room.
Four-way Cassette MCAC-VTSM-2017-01 9. Sound Levels 9.1 Test condition Four-way cassette type 1.4m Note: 1, During actual operation, these values are normally somewhat higher as a result of ambient conditions. 2, Semi-anechoic chamber conversion value, measured at a point which is 1.4m under the unit. 9.2 Test data (Sound Pressure Levels) Sound level under three speeds of fan (dB(A)) Model...
Page 80
MCAC-VTSM-2017-01 Four-way Cassette MDV-D90 (100,112) Q4/N1-D MDV-D140Q4/N1-D Audibility limits of Audibility limits of continuous white continuous white sound sound Octave band center frequency ( Hz ) Octave band center frequency ( Hz )...
Four-way Cassette MCAC-VTSM-2017-01 10. Accessories Name Quantity Shape Washer Installation paper board Bolt M6 Electric throttle(That have been installed at the unit) Connective pipe for restriction assembly Soundproof / insulation sheath SpongeⅠ(250*250*10) SpongeⅡ(60*100*5) Drain pipe sheath Drain pipe clasp Tightening band Flexible hose tube Signal line Remote controller...
Silent Four-way Cassette MCAC-VTSM-2017-01 1. Features External appearance Regardless of difference in capacity, all indoor units feature the same panel size and design, in consideration or harmonized interior decoration. Four way uniform airflow Four air discharge ports provide strong air flow circulation to cool or heat every corner of a room and evenly distribute temperature.
Page 84
MCAC-VTSM-2017-01 Silent Four-way Cassette Built-in electronic throttle components make the installation easier. Flexible air distribution type 7 discharge patterns in 2 to 4 directions can be selected to suit the requirements of installation site or the shape of the room. Duct connection is possible.
Silent Four-way Cassette MCAC-VTSM-2017-01 2. Specifications Model MDV-D28Q4/N1-E MDV-D36Q4/N1-E MDV-D45Q4/N1-E Power supply 1 phase, 220-240V, 50Hz Capacity Cooling Power input Rated current 0.31 0.31 0.41 Capacity Heating Power input Rated current 0.31 0.31 0.41 Model YDK26-6S Type Insulation class Indoor fan motor Safe class IP20 Input...
Page 86
MCAC-VTSM-2017-01 Silent Four-way Cassette Specifications Model MDV-D56Q4/N1-E MDV-D71Q4/N1-E MDV-D80Q4/N1-E Power supply 220-240V~ 50Hz Capacity Cooling Power input Rated current 0.41 0.41 0.48 Capacity Heating Power input Rated current 0.41 0.41 0.48 Model YDK26-6S YDK30-6S YDK37-6S Type Insulation class Indoor fan motor Safe class IP20 Input...
Page 87
Silent Four-way Cassette MCAC-VTSM-2017-01 Specifications MDV- MDV- MDV- MDV- Model D90Q4/N1-E D100Q4/N1-E D112Q4/N1-E D140Q4/N1-E Power supply 220-240V~ 50Hz Capacity 11.2 Cooling Power input Rated current 0.67 0.72 0.72 0.75 Capacity 11.1 12.5 Heating Power input Rated current 0.67 0.72 0.72 0.75 Model YDK50-6S...
Silent Four-way Cassette MCAC-VTSM-2017-01 4. Service spaces There is enough room for installation and maintenance. The ceiling is horizontal, and its structure can endure the weight of the indoor unit. The outlet and the inlet are not impeded, and the influence of external air is the least. The air flow can reach throughout the room.
MCAC-VTSM-2017-01 Silent Four-way Cassette 5. Piping diagrams motor flare nut gas side heat exchanger flare nut liquid side T1: Indoor ambient temperature sensor; T2: Temperature sensor in the middle of evaporator; T2B: Evaporator outlet temperature sensor. Refrigerant pipe connection port diameters Model Gas pipe Liquid pipe...
MCAC-VTSM-2017-01 Silent Four-way Cassette 9. Sound levels Four-way cassette type 1.4m Note: 1. Sound values are measured in a semi-anechoic room, at a position 1.4m downward from the unit center 2. During actual operation, these values are normally somewhat higher as a result of ambient conditions. Sound pressure level dB(A) Model MDV-D28Q4/N1-E...
MCAC-VTSM-2017-01 Silent Four-way Cassette 10. Accessories Attached accessories Name Shape Quantity Washer Installation paper board Bolt M6 Connection pipe Soundproof / insulation sheath Sponge (250×250×10) Sponge (60×100×5) Outlet pipe sheath Outlet pipe clasp Tightening band Flexible hose tube Signal line Remote controller Frame Alkaline dray batteries (AM4)
Page 105
Commercial Air Conditioner Division Midea Group Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde, Foshan, Guangdong, China Postal code: 528311 Midea CAC After-service Application Midea CAC News Application Tel: +86-757-26338346 Fax: +86-757-22390205 cac.midea.com global.midea.com Note: Product speci cations change from time to time as product improvements and developments are released and may vary from those in this document.