Repair; Replace Air Filter Element - Graco XM Series Repair Parts

Plural-component sprayers
Hide thumbs Also See for XM Series:
Table of Contents

Advertisement

Repair

To avoid injury due to unexpected machine operation
initiated by a remote controller, disconnect the
customer I/O cable from the system prior to repair.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure on page 17 and disconnect power from
the system before repairing the equipment.
Follow Park Fluid Pump Rods procedure, page 24, if
service time may exceed pot life time, before servicing
fluid components, and before transporting sprayer to a
service area.

Replace Air Filter Element

There are two air filters on the system: the inlet air
regulator filter on the air controls and the main air inlet
manifold filter. Check filters weekly and replace element
as needed.
Removing a pressurized air filter bowl could cause
serious injury. Do not service air filter until air line is
depressurized.
Control Air Regulator Filter
1. Close main air shutoff valve on air supply line and
on unit. Depressurize air line.
2. Remove front and rear shrouds (12, 13). Remove
four nuts (14) and then shrouds.
13
313289W
12
14
3. Unscrew filter bowl from inlet air regulator (344).
4. Remove and replace element.
5. Screw filter bowl on securely.
Main Air Inlet Manifold Filter
1. Close main air shutoff valve on air supply line and
main air valve (E) on unit. Depressurize air line.
2. Unscrew filter bowl (D) from main air valve (E).
3. Remove and replace filter element (601a). See Air
Inlet Manifold (26C689) Parts, page 88.
4. Reassemble filter bowl.
5. Replace front and rear shrouds (12, 13) using four
nuts (14).
Repair
344
Filter Bowl
and Element
29

Advertisement

Table of Contents
loading

Table of Contents