4.  Open  the  funnel  plug  and  pour  the 
sanitizing solution in the reservoir and 
wait at least 10 minutes 
 
5.  Unscrew  the  two  fastening  screws 
and remove the bin cover   
 
 
 
6.  Lift  up  the  ice  level  control  and  its 
bracket  from  its  housing  and  carefully 
stand it on the frame of the unit 
Remove ice, distribution vane and steel 
bottom from the storage bin 
 
 
  
7. Using the same carafe, prepare again 
500 ml of warm water (40‐50°c) and 15 
 
ml of Scotsman Sanitizing product and 
pour  of  the  solution  on  the  internal 
sides of the storage bin 
 
8.  Using  a  sanitised  disposable  cloth, 
clean  the  ice  bin  and  rinse  with  clean 
water.  
 
 
9. Close the funnel plug and reinstall all 
the  previously  removed  panels  and 
parts  by  following  the  procedure  in 
reverse  order,  paying  attention  that 
both  the  steel  bottom  and  the  upper 
shaft of the blade are properly seated. 
 
 