Troubleshooting - Bradford White D4403S*F(BN Service Manual

Residential flue damper
Table of Contents

Advertisement

Observe the green LED on the water heater gas
control.
Error codes are displayed with a 3 second
pause before repeating. Once the error code is known,
check and repair the water heater, as recommended in
the table below.
LED Status
Control Status
None (LED
Electrical power not
not on or
present
flashing)
One short
Stand-by mode,
flash every
Thermostat is
four seconds
satisfied (no faults)
Alternates
bright and
Thermostat calling
dim
for heat (no fault)
(heartbeat)
Short flash
Weak pilot signal
once every
on last call for heat
second
Two flashes,
Damper test circuit
three second
not working
pause
Three
flashes,
Damper test circuit
three second
not working
pause
Excessive tank
Four flashes,
temperature,
three second
system must be
pause
reset
Five flashes,
False pilot flame
three second
present
pause
Six flashes,
one flash,
Failed to light pilot,
three second
system resets after
pause (Soft
(5) minutes
Lockout)
Probable Cause
Control power switch in "OFF"
position.
Supply voltage interrupted.
Temperature demand is satisfied
(no call for heat)
Tank temperature below
setpoint of thermostat
1. Unstable pilot
2. Pilot tube blocked or restricted
3. Oxidation build-up on pilot
electrode
4. Wire damage to pilot
assembly or bad connection at
gas control
1. Damper not in proper position
or malfunctioning - stuck in open
position
2. Obstructed venting
3. Faulty damper
1. Damper not in proper position
or malfunctioning - not reaching
full open position
2. Obstructed venting
3. Faulty damper
1. Thermal well sensor out of
calibration
2. Faulty gas control
Pilot valve stuck in open position Replace gas control
1. Unstable pilot
2. Pilot tube block or restricted
3. Oxidation build-up on pilot
electrode
4. Wire damage to pilot
assembly or bad connection at
gas valve

Troubleshooting

Green LED
Service Procedure
Turn Power On
Normal operation
Normal operation
1. See Burner Inspection on
page 15
2-4. See Pilot Inspection,
Testing and Replacement on
page 17
1. Verify cord sets are fully
plugged in
2. Verify switch on damper is
in "Automatic" position
3. Verify that damper and
venting is not obstructed
1. Verify cord sets are fully
plugged in
2. Verify switch on damper is
in "Automatic" position
3. Verify that damper and
venting is not obstructed
1. Test Gas Control & Thermal
Well
2. Replace gas control if
necessary
1. See Burner Inspection on
page 15
2-4. See Pilot Inspection,
Testing and Replacement on
page 17
Page 13
13