Overview of F150-2 Application
Distance from Measurement Object
The Camera must be mounted at a distance from the measure-
ment object where it can correctly view the object. The lens focus
is fixed and the distance must be adjusted each time the lens or
Camera is changed because the field of vision and focus vary
from lens to lens.
The camera's set distance is an approximate value. The cam-
era's mounting allows it to be adjusted slightly nearer to or farther
from the object.
F150-SL20A/SL50A
Measurement
object
Mounting the Camera
The specified camera distance is only an approximation. Mount
the Camera so that it can be adjusted to either side of the speci-
fied distance from the measurement object.
Camera with Light Source
If the object size and field of vision are incompatible, attach a
standard CCTV lens and light to the Camera.
16
Field of Vision (H × W)
20-mm lens: 20 × 20 mm
50-mm lens: 50 × 50 mm
Two M4 holes with
a depth of 8 mm
1/4-20UNC with
a depth of 8 mm
Mounting dimensions
Camera distance
20-mm lens: 61 to 71 mm
50-mm lens: 66 to 76 mm
Camera
Section
2-5
p. 63
Unit: mm
Two M4 holes with
a depth of 8 mm
1/4-20UNC with
a depth of 8 mm