Maintenance and repair

Bosch Rexroth AG, A2FM/A2FE/A2FMT Series 70, RE 91071-01-B/06.2018
10 Maintenance and repair
Overdue inspection and maintenance work!
Risk of property damage!
Perform the specified inspection and maintenance work at the intervals
described in this manual.

10.1 Cleaning and care

Damage to seals and electrical system due to mechanical effects!
The jet of a high-pressure cleaner may damage the seals and electrical system of
the axial piston unit!
Do not point a high-pressure cleaner at sensitive components, e.g. shaft seal,
electrical connections and components.
For cleaning and care of the axial piston unit, observe the following:
Check whether all seals and plug-in connections are securely seated to ensure
that no moisture can penetrate into the axial piston unit during cleaning.
Use only water and, if necessary, a mild cleaning agent to clean the axial piston
unit. Never use solvents or corrosive cleaning agents.
Remove major external contamination and keep clean sensitive and important
components, such as solenoids, valves, displays and sensors.