Sony RCP-3100 Operating Instructions Manual page 5

Remote control panel
Table of Contents

Advertisement

MCS mode connection example
HDC3100
• The master device controls the whole camera system.
• Configure the IP address of each device and the IP address of the master device.
• A master setup unit (MSU) or CNA-1 can be used as the master device.
• Centralized control of devices and assignment of device to control (RCP assignment) are
supported using MSU and HZC-CSM1.
HDCU3100
CNS: MCS
IP address: 192.168.0.1
Master IP address: 192.168.0.201
CCU No.: 1
CNS: MCS
IP address: 192.168.0.2
Master IP address: 192.168.0.201
CCU No.: 2
CNS: MCS
IP address: 192.168.0.n
Master IP address: 192.168.0.201
CCU No.: n
5
Master device
MSU-1500
CNA-1
or
LAN
cable
LAN
cable
LAN
cable
PoE hub
LAN
cable
CNS: MCS
IP address: 192.168.0.201
Master/Client: Master
Device No.: (1)
RCP-3100
LAN
cable
CNS: MCS
IP address: 192.168.0.101
Master IP address: 192.168.0.201
RCP No.: 1
LAN
cable
CNS: MCS
IP address: 192.168.0.102
Master IP address: 192.168.0.201
RCP No.: 2
LAN
cable
CNS: MCS
IP address: 192.168.0.(100+m)
Master IP address: 192.168.0.201
RCP No.: m

Advertisement

Table of Contents
loading

Table of Contents