FB2100/FB2200 Flow Computer CPU Enclosure and Electronics Field Replacement Guide

Removing/Replacing the Connectivity Board

UL Listed Connectivity Board Field Installed Accessory Kit for Use in Class I, Division 2,
Groups A, B, C, D
 Flow Computer Connectivity Board Field Installed Accessory Kit Part No.
The connectivity board provides connections to the CPU board as well as the optional
6-channel expansion I/O board inside the CPU enclosure.
1.
Connectivity Board
2.
Connectivity board connector to the CPU board
3.
Connectivity board connector to the optional 6-channel expansion I/O board
4.
Ethernet port (active on FB2200 only)
The connectivity board sits on the side of the CPU enclosure. It has two connectors
that go through the bottom of the CPU enclosure to mate with the termination I/O
board, and an Ethernet port (active on FB2200 only), that goes through the side of the
CPU enclosure.
400211010-KIT for use with UL Listed Model Series FB2100 and FB2200.