FB2100/FB2200 Flow Computer CPU Enclosure and Electronics Field Replacement Guide
4. Gently pull the CPU enclosure out of the flow computer enclosure.

Re-attaching the CPU Enclosure to the Battery Compartment

1. Line up the CPU enclosure's captive fastening screws with their matching holes on
the other assemblies and battery compartment. Press the enclosure screws onto
the holes and hold the CPU enclosure while tightening each of the captive
fastening screws with a torque of 7 to 9 in-lbs (0.8 to 1.0 N m).
2. Connect the cable between the CPU and the sensor module and make sure it has
clearance.
3. Replace the HMI module. See Replacing the HMI Module on page 7.