Maintenance

Daily Maintenance

For overnight shutdown, stop the pump at the bottom
of its stroke to prevent damaging the pump rod and
throat packings.
1. Follow the Flushing and Cleaning procedure on
page 20.
2. Follow the Pressure Relief Procedure on page 15.
3. Use the included spanner wrench to make sure the
packing nut (D) is just tight. Refill with Throat Seal
Liquid (TSL
) as needed.
4. Check all hoses and fitting connections for leaks.
Tighten all connections before each use.
5. Check hoses for damage every time you spray. Do
not attempt to repair the hose if the hose jacket or
fittings are damaged. Replace all damaged parts.
24
NOTICE
D

Cart Maintenance

Periodically lubricate the axle between points A and B
with lightweight oil (see below).