Thermostat - Mitsubishi Fuso CANTER FE85DE6SLGP Shop Manual

Euro 4 for colombia 4m5 diesel engine
Table of Contents

Advertisement

THERMOSTAT

Service standards (Unit: mm)
Location
2
Thermostat
Inspection procedure
Installation procedure
14-26
Maintenance item
Valve opening temperature
Valve lift at 95°C
• Stir the water using a stirring rod to maintain an even water tem-
• If the measured values deviate from the standard value ranges,
(1) Valve opening temperature
• Hold the thermostat with wire to keep it away from the heat
• Heat the water gradually to the valve opening temperature.
• Maintain this temperature for five minutes and make sure that
• Make sure that the valve closes completely when the water tem-
(2) Valve lift
• Raise the water temperature to 95°C to fully open the valve.
• Mount the thermostat on the thermostat cover in the illustrated
Follow the disassembly sequence in re-
verse.
Standard value
82 ± 2°C
10 or more
Inspection: Thermostat
perature in the container, then conduct the tests indicated below.
replace the thermostat.
source.
the valve is completely open.
perature drops below 65°C.
Keep this condition for 5 minutes and then measure the valve lift.
Installation: Thermostat
direction.
Disassembly sequence
1 Thermostat cover
2 Thermostat
*
a: Oil cooler
Assembly sequence
Limit
Remedy
Replace