Installation; Terminal Arrangement - Omron H7BR Series Manual

Digital counter
Hide thumbs Also See for H7BR Series:
Table of Contents

Advertisement

H7BR

Installation

Terminal Arrangement

H7BR-B (standard type)
1 Stage, Contact and NPN
Transistor Outputs
Reset input
H7BR-B
H7BR-BV
0 V
8
Batch count reset
15
(-)
Key protection input
16
1
(–)
1 Stage, Contact and PNP
Transistor Outputs
Reset input
H7BR-BP
H7BR-BVP
0 V
8
Batch count reset
15
(-)
Key protection input
16
1
(–)
2 Stages, Contact and NPN
Transistor Outputs
Reset input
H7BR-BW
H7BR-BWV
0 V
8
Batch counter reset
15
(-)
Key protection input
16
1
(–)
20
CP2 input
CP1 input
Gate input
12/24 VDC
Output common
9 10 11 12 13 14
Sensor
power supply
17
Unused
(+)
OUT
18
OUT
Batch
2
3
4
5
6
7
Unused
100 to 240 VAC/24 VAC
12 to 24 VDC
(+)
CP2 input
CP1 input
Gate input
12/24 VDC
Output common
9 10 11
12
13
14
Sensor
power supply
17
Unused
(+)
OUT
18
OUT
Batch
2
3
4
5
6
7
Unused
100 to 240 VAC/24 VAC
(+)
12 to 24 VDC
CP2 input
CP1 input
Gate input
12/24 VDC
Output common
9 10 11
12
13
14
OUT 1
Sensor
power supply
17
(+)
OUT 2
18
OUT 2
OUT 1
Batch
2
3
4
5
6
7
100 to 240 VAC/24 VAC
12 to 24 VDC
(+)
±
H7BR-C (
range type)
1 Stage, Contact and NPN
Transistor Outputs
Reset input
H7BR-C
H7BR-CV
0 V
(-)
8
Compensation input
(-)
15
Key protection input
16
1 2
(–)
1 Stage, Contact and PNP
Transistor Outputs
Reset input
H7BR-CP
0 V
H7BR-CVP
8
Compensation input
15
(-)
Key protection input
16
1
(–)
2 Stages, Contact and NPN
Transistor Outputs
Reset input
H7BR-CW
H7BR-CWV
0 V
8
Compensation input
15
(-)
Key protection input
16
1
(–)
H7BR
CP2 input
CP1 input
Gate input
12/24 VDC
Output common
(+)
9 10 11
12
13
14
Sensor
power supply
17
Unused
(+)
OUT
18
OUT
3
4
5
6
7
Unused
100 to 240 VAC/24 VAC
12 to 24 VDC
(+)
CP2 input
CP1 input
Gate input
12/24 VDC
Output common
9 10 11
12
13
14
Sensor
power supply
17
Unused
(+)
OUT
18
OUT
2
3
4
5
6
7
Unused
100 to 240 VAC/24 VAC
12 to 24 VDC
(+)
CP2 input
CP1 input
Gate input
12/24 VDC
Output common
9 10 11
12
13
14
OUT 1
Sensor
power supply
17
(+)
OUT 2
18
OUT 2
OUT 1
2
3
4
5
6
7
Unused
100 to 240 VAC/24 VAC
12 to 24 VDC
(+)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H7br-bH7br-c