8.3 History

The "History" menu can be used to query the runtimes of the
compressor(s), circulating pumps and further components in the
heat pump heating system.
You can access the history menu by:
Pressing the button (MENU) for approx. 5 seconds
EN-14
Selecting the history menu item with the arrow buttons and
confirming with the ENTER button
Depending on the system configuration, the following data is
available:
Display of runtimes and stored data
Total runtime of compressor 1
Total runtime of compressor 2
Total runtime of 2nd heat generator
Total runtime of the brine circulating pump or well pump. The
runtime is greater than the total of the compressor runtimes
because of pump forerun and afterun.
Total runtime of the ventilator. The runtime is less than the total of
the compressor runtimes because of the defrosting process (the
ventilator is switched off during defrosting).
Total runtime of the heat circulating pump
Runtime of the compressor in cooling operation
Total runtime of the hot water circulating pump
Total runtime of the swimming pool circulating pump
Runtime during which the flange heater was additionally switched
on for DHW preparation
Displays the last fault which occurred with the date, time and
cause
Displays the second to the last fault which occurred with the date,
time and cause
Displays the start and end of the last, fully completed initial heating
program
Displays the start and end of the last, fully completed screed drying
program
The quantity of thermal energy supplied by the heat pump is
totalled and displayed. The quantity of thermal energy displayed
can be reset here.
The quantity of thermal energy supplied by the heat pump during
heating operation is displayed here.
The quantity of thermal energy supplied by the heat pump during
heating operation is displayed here. During parallel operation (with
additional heat exchanger (DHW) and heating) the quantity of
thermal energy is counted together here. The quantity of thermal
energy can be reset here.
Display
Always
2 compressors
Bivalent or mono
energy
BW or WW HP
AW HP
Always
Reversible HP
Hot water
Swimming pool
Hot water sensor
Flange heater
Always
Always
Always
Always
therm. energy
meter
domestic hot
water
swimming pool
therm. energy
meter
therm. energy
meter
desuperh.
No external
thermal energy
meter