8.2
EN-12
Display of sensor and system values
Displays the measured flow temperature (R4) during cooling
operation measured at the heat exchanger output
Displays the temperature measured by the hot gas sensor (R18)
Displays the temperature measured in the room in which room
climate control station 1 is installed.
This temperature is the controlled variable for silent cooling in
heating circuit 1/2.
Displays the humidity measured in the room in which room climate
control station 1 is installed. This value is used for calculating the
dew point with silent cooling in heating circuit 1/2.
Displays the temperature measured in the room in which room
climate control station 2 is installed.
This value is used for calculating the dew point with silent cooling
in heating circuit 3.
Displays the current humidity in the room in which room climate
control station 2 is installed. This value is used for calculating the
dew point with silent cooling in heating circuit 3.
Indicates whether a cooling request has been made. Even if a
request is pending, it is possible that the heat pump still does not
operate (e.g. frost protection). This block is shown by the
preceding lock symbol
.
Displays the current domestic hot water set temperature
Displays the measured domestic hot water temperature (R3). This
temperature is the controlled variable for DHW preparation.
Indicates whether a request for domestic hot water has been
made. Even if a request is pending, it is possible that the heat
pump still does not operate (e.g. programmed shut-off times,
operating limits, heating up). This block is shown by the preceding
lock symbol
. A HP block combined with a sufficiently high
cylinder temperature is indicated by "Bivalent-renewable".
Displays the current swimming pool temperature (R20). This is the
controlled variable.
Indicates whether a request for swimming pool water has been
made. Even if a request is pending, it is possible that the heat
pump still does not operate (e.g. programmed shut-off times,
operating limits, heating up). This block is shown by the preceding
lock symbol
. A HP block combined with a sufficiently high
cylinder temperature is indicated by "Bivalent-renewable".
Displays the temperature measured at the heat source (R6) output
or the refrigerating circuit output of the HP. This temperature
serves to safeguard the lower operating limit.
Displays the current pressure (R26) on the high-pressure side.
Displays the current pressure (R25) on the low-pressure side.
Display of the heat source temperature (R24) for a reversible heat
pump with electronic expansion valve
Displays the heat source temperature (R24) in combination
systems.
Display
Cooling function
passive
Reversible HP
Cooling function
silent cooling
Heating circuit 1/2
or
room regulation
Cooling function
silent cooling
Heating circuit 1/2
Cooling function
silent cooling
Heating circuit 3
Cooling function
silent cooling
Heating circuit 3
Cooling function
cooling
Hot water
sensors
Hot water
sensor
Hot water
Swimming pool
sensor
Swimming pool
BW o. WW HP
with integr.
controller
Pressure sensor
Pressure sensor
BW o. WW HP
Reversible
electronic expa.
valve
Cooling
Cooling function