Heating request
A heating request is pending if the "Return set temperature" minus the
"Hysteresis return temperature" is higher than the current measured
"Return temperature".
.
Display of sensor and system values
Displays the heat pump type identified from the coding
resistor(R7).
Displays the heating controller software version including the boot
and bios version, as well as the valid network address.
Displays whether the two extension modules are available for
cooling.
The quantity of thermal energy supplied by the heat pump is
totalled and displayed. The quantity of thermal energy displayed
can be reset here.
The quantity of thermal energy supplied by the heat pump during
heating operation is displayed here.
The quantity of thermal energy supplied by the heat pump during
heating operation is displayed here. During parallel operation (with
additional heat exchanger (DHW) and heating) the quantity of
thermal energy is counted together here. The quantity of thermal
energy can be reset here.
The quantity of thermal energy supplied by the heat pump during
domestic hot water operation is displayed here. The quantity of
thermal energy can be reset here.
The quantity of thermal energy supplied by the heat pump during
swimming pool operating mode is displayed here. The quantity of
thermal energy can be reset here.
Displays all stored maximum heat pump temperatures.
8.2
Display
Always
Always
Cooling function
therm. energy
meter
domestic hot
water
swimming pool
therm. energy
meter
therm. energy
meter
desuperh.
therm energy
meter
domestic hot
water
therm energy
meter
swimming pool
domestic hot
water
EN-13