Water Inlet Fault - Miele G 7960 C SCVi Operating Instructions Manual

Table of Contents

Advertisement

Problem solving guide

Water inlet fault

Problem
The optical in-operation
indicator light is
flashing quickly.
The alarm tone is
sounding.
One of the following
messages appears in
the display:
 
Please open the
stopcock
 
Insufficient water intake.
Open the stopcock fully.
Refer to operating
instructions if necessary
Fault F 18: A technical
fault has occurred. Switch
the appliance off, close the
stopcock and call Miele
Service.
The following fault
message appears on
the display during the
SolarSave
 programme:
Intake temperature too low
100
Cause and remedy
The stopcock is closed.
 Open the stopcock fully.
Before rectifying the problem:
 Switch the dishwasher off.
The water inlet is restricted.
 Open the stopcock fully and start the programme
again.
 Clean the filter in the water inlet (see "Cleaning
and care" – Cleaning the filter in the water inlet").
 The water-connection pressure is lower than
50 kPa.
Seek professional advice.
 The on-site connection for the water drainage may
be too low and you will need to vent the water
drainage (see "Installation – Water drainage").
A technical fault has occurred.
 Switch the dishwasher off.
 Close the stopcock.
 Call the Miele Customer Service Department.
The intake water has not reached the required
temperature of 45 °C (see "Installation – Water inlet").
 Start the programme again.
 If the fault message appears again, select a
different programme.

Advertisement

Table of Contents
loading

Table of Contents