3M 6000DIN Series User Instructions page 7

Full facepiece respirator
Table of Contents

Advertisement

Available languages

Available languages

3M recommended for relief against nuisance levels of acid gas or organic vapors. Nuisance level refers to concentrations not exceeding OSHA PEL or
1
applicable exposure limits, whichever is lower. Do not use for respiratory protection against acid gas/organic vapors.
3M recommended for ozone protection up to 10 times the OSHA PEL or applicable government occupational exposure limits, whichever is lower.
2
NOTE: Not NIOSH approved for use against ozone.
3M™ Particulate Filters must be immediately changed when an increase in breathing resistance is noticed.
Assembly Instructions
All 3M™ Full Facepieces 6000 Series equipped with the 3M™ DIN Port Adapter 6884 (full facepiece assemblies 6700DIN, 6800DIN and 6900DIN)
can be used in any of the following configurations:
Powered Air-Purifying Respirator (PAPR):
– 3M™ GVP Belt-Mounted PAPR with 3M™ Breathing Tube GVP-123
– 3M™ Powerflow™ Face-Mounted PAPR
– 3M™ Breathe Easy™ Belt-Mounted PAPR with 3M™ Breathing Tube 520-01-77
Supplied Air Respirator (SAR):
– 3M™ Dual Airline
– 3M™ Air Control Devices – Continuous Flow (excluding Air Regulating Kit W-3196 and stainless steel options)
Negative Pressure:
– 3M™ Responder Cartridge FR-64 and CP3N Canister (Front-Mounted)
– 3M™ Filters 2000 Series, Filters 7093/7093C and Cartridges 6000 Series (Side-Mounted)
Whenever the air filtration/supply system, including responder canisters or cartridges are attached to the center DIN port of the DIN Port Adapter
Assembly 6884, the 3M™ Full Face Plug 7890 must be removed from the center port and the two bayonet ports must be closed using Bayonet Caps
6880 and Inhalation Port Gaskets 6895.
NOTE: Make certain 3M™ Inhalation Port Gaskets 6895 are in place on the facepiece bayonet connectors before installing filters, cartridges or
breathing tubes.
3M™ Cartridge 6000 Series, Filter 7093 and Cartridge/Filter 7093C
1. Align the cartridge notch with the small solid bayonet lug on facepiece and push together.
2. Turn cartridge clockwise to stop (1/4 turn).
3. Repeat with second cartridge (Fig. 1).
4. Check that a breathing tube gasket (gray) 6876 and plug 7890 have been installed in the center DIN port.
3M™ Filters 2000 Series
1. Align opening of filter with filter attachment on facepiece.
2. Turn filter clockwise until it is firmly seated and cannot be further turned.
3. Repeat for second filter (Fig. 2).
4. Check that a breathing tube gasket (gray) 6876 and plug 7890 has been installed in the center DIN port.
Fig. 1
6800 w/6000cart turn/6884.eps
2/20 2001 K&K
6
(English)

Advertisement

Table of Contents
loading

This manual is also suitable for:

670068006900071380713907140

Table of Contents