Troubleshooting - Senco FUSION F-35XP Operating Instructions Manual

Cordless framing nailer
Hide thumbs Also See for FUSION F-35XP:
Table of Contents

Advertisement

Troubleshooting

Problem/symptom
Pressing mode switch does not
result in green light.
Red light on.
Red light flashes.
note: if tool has jammed and the mechanism initiates an automatic recovery, the tool may make a series
of clicks as it repositions the driver. This is normal.
Red light fades every 1.4 seconds.
Tool will not start or runs slowly.
Probable Cause
Check battery.
PCB is not energized.
Electronic components damaged.
Low battery.
Maintenance required.
Fastener jam.
Tool does not function.
Internal high temperature.
Battery is discharged or has dead
cell.
Workpiece contact element is
jammed.
Workpiece contact element or
trigger switches are damaged.
20
Corrective action
Remove and reattach.
Pull trigger once to energize board.
Then choose mode selector.
Return to an authorized service
center.
Recharge or replace battery.
Check battery connection at tool.
Is tool power good? If tool power
seems low, return to service center
for pressure check
Tool will attempt to recover.
Did fastener drive ok?
**remove Battery**
Check if nail is blocking next
fastener.
Inspect magazine for bent nail.
Remove magazine and inspect
guide body.
Return to service center for repair.
Allow tool to cool at least 15
minutes.
Tool will completely cool in 30
minutes.
Replace or recharge battery.
Remove battery, then inspect
tool to assure free movement of
workpiece contact element.
Return tool to authorized SENCO
service representative.

Hide quick links:

Advertisement

Table of Contents
loading