York YMA024 Technical Manual page 4

Affinity r-22 split-system heat pumps
Hide thumbs Also See for YMA024:
Table of Contents

Advertisement

036-21570-002 Rev. D (0605)
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
MODEL
N1AHB08
YMA02411
N1AHB12
N1AHB08
YMA03011
N1AHB12
N1AHB08
N1AHB12
YMA03611
N1AHC16
N1AHC16
YMA04211
N1AHD20
N1AHD20
YMA04811
N1AHD20
N1AHD20
YMA06011
N1AHD20
YMA02411
N1VSB12
YMA03011
N1VSB12
N1VSB12
YMA03611
N1VSC16
N1VSC16
YMA04211
N1VSD20
N1VSD20
YMA04811
N1VSD20
N1VSD20
YMA06011
N1VSD20
F2RC/F2FC036
YMA02411
F2RP/F2FP/F3FP024
F2RP/F2FP/F3FP030
F2RC/F2FC036
YMA03011
F2RP/F2FP/F3FP030
F2FP/F3FP040
F2RP/F2FP/F3FP036
YMA03611
F2RP/F2FP/F3FP042
F2FP048
YMA04211
F2FP/F3FP060
YMA04811
F2FP045
F2FP060
YMA06011
F2FV060
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU's at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1
G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2
Single phase units require single phase 2HK heaters.
3
To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
4
FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard.
**
Refer to Quick Selection Chart for specific furnace match-up.
4
AIR HANDLER
2
ELECTRIC
W
HEAT KW
1 PH 12 SEER HP WITH N1AH / G2FD
2,5,8,10
17
2,5,8,10
17
2,5,8,10
17
2,5,8,10
17
2,5,8,10
17
2,5,8,10
17
5,8,10,15,20
21
5,8,10,15,20
21
8,10,15,20,25,30
24
8,10,15,20,25,30
24
8,10,15,20,25,30
24
8,10,15,20,25,30
24
8,10,15,20,25,30
24
1 PH 12 SEER HP / N1VS - VARIABLE SPEED
2,5,8,10
17
2,5,8,10
17
2,5,8,10
17
5,8,10,15,20
21
5,8,10,15,20
21
8,10,15,20,25,30
24
8,10,15,20,25,30
24
8,10,15,20,25,30
24
8,10,15,20,25,30
24
8,10,15,20,25,3
24
1 PH 12 SEER HP / F2RP / RC / FP / FC / FV
5,8,10,15
18
5,8,10,15
18
5,8,10,15
18
5,8,10,15
21
5,8,10,15
21
5,8,10,15
21
5,8,10,15
21
5,8,10,15
21
5,8,10,15,20,25
24
8,10,15,20,25
24
5,8,10,15
24
8,10,15,20,25
24
8,10,15,20,25
24
1
COIL
RATED
MODEL
CFM
G2FD030(S,H)17(T)
800
G2FD030(S,H)17(T)
800
G2FD030(S,H)17(T)
1000
G2FD030(S,H)17(T)
1000
G2FD036(S,H)17(T)
1200
G2FD036(S,H)17(T)
1200
G2FD036(S,H)21(T)
1200
G2FD048(S,H)21(T)
1400
G2FD048(S,H)24(T)
1400
G2FD060(S,H)24(T)
1600
G2FD061H24
1600
G2FD060(S,H)24(T)
1800
G2FD061H24
1800
G2FD030(S,H)17(T)
775
G2FD030(S,H)17(T)
1000
G2FD036(S,H)17(T)
1200
G2FD036(S,H)21(T)
1200
G2FD048(S,H)21(T)
1380
G2FD048(S,H)24(T)
1350
G2FD060(S,H)24(T)
1600
G2FD061H24
1600
G2FD060(S,H)24
1780
G2FD061H24
1780
-
800
-
800
-
800
-
1000
-
1000
-
1200
-
1200
-
1200
-
1400
-
1600
-
1600
-
1800
-
1780
.
models. All ratings remain the same.
COOLING
TOTAL
SENSIBLE
SEER
CAPACITY
CAPACITY
W/O TXV
24.0
18.8
12.00
24.0
18.8
12.00
30.0
23.0
12.00
30.0
23.0
12.00
35.2
27.2
12.00
35.2
27.2
12.00
35.6
28.0
12.00
42.0
32.8
12.00
42.0
32.8
12.00
46.0
35.6
46.0
36.0
54.0
42.2
11.70
54.5
42.4
12.00
24.2
18.5
13.00
30.2
22.8
13.00
35.4
26.8
12.50
36.0
27.6
13.00
42.5
32.4
13.00
42.5
32.0
13.00
46.0
35.0
46.5
35.4
53.5
40.6
12.00
54.5
41.4
12.10
3,4
24.0
18.8
12.00
23.6
18.6
12.00
24.0
18.8
12.00
29.6
22.2
12.00
29.6
22.2
12.00
36.0
27.2
12.00
35.8
27.0
12.00
36.0
27.2
12.00
41.5
31.8
12.00
45.5
34.2
45.5
34.5
53.0
40.4
11.25
54.0
40.8
12.00
Unitary Products Group
SEER
EER
W/ TXV
12.00
10.90
12.00
10.90
12.00
11.10
12.00
11.10
12.00
11.05
12.00
11.05
12.00
11.30
12.00
10.70
12.00
10.70
-
12.00
10.20
-
12.00
10.25
-
10.50
-
10.55
13.00
11.95
13.00
11.95
12.50
11.65
13.00
12.20
13.00
11.45
13.00
11.40
-
12.50
10.65
-
12.50
10.70
-
10.65
-
10.85
12.00
10.90
12.00
10.90
12.00
10.90
12.00
11.05
12.00
11.05
12.00
11.30
12.00
11.20
12.00
11.30
12.00
10.55
-
11.50
10.00
-
12.00
10.20
-
10.25
-
10.75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yma02411Yma03011Yma03611Yma04211Yma04811Yma06011

Table of Contents