York PV9 Technical Manual

York PV9 Technical Manual

Gas-fired condensing / high efficiency two stage variable upflow furnaces

Advertisement

TECHNICAL GUIDE
AFFINITY
MODELS: PV9
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
TWO STAGE VARIABLE
UPFLOW FURNACES
UP TO 94% AFUE
NATURAL GAS
40 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room
or garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented
using approved plastic type combustion air and vent piping.
All units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the
original purchaser; a 20-year limited warranty from original
installation date to subsequent purchaser.
10-year warranty on commercial applications.
5-year limited parts warranty.
FEATURES
Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
- Variable speed ECM blower operation
Provides increased comfort level & very quiet unit oper-
ation
Adjustable delay timer allows two stage operation with
single stage thermostat
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-
tion.
• Integrated control module for reliable, economical opera-
tion.
• High velocity filter and side -return filter rack provided for
easy field installation.
• May be installed as either two-pipe (sealed combustion)
or single pipe vent (using indoor combustion air)
• Top intake & vent connection allows installation in narrow
locations.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• Induced combustion system with inshot main burners for
quiet, efficient operation.
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• 24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-
grade stainless steel.
• Timed on, adjustable off blower capability for maximum
comfort.
• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance
or service.
• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
• ClimaTraK comfort system allows dealer to customize
comfort settings based on regional location.
036-21584-001 Rev. B (1004)

Advertisement

Table of Contents
loading

Summary of Contents for York PV9

  • Page 1 RATING CERTIFIED Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.gamanet.org. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE...
  • Page 2: Combustion Air Supply And Vent Piping

    036-21584-001 Rev. B (1004) 26-1/2 24-5/8 1-1/2” GAS PIPE ENTRY 7/8” JUNCTION BOX HOLE T-STAT WIRING 7/8” K.O. CONDENSATE DRAIN 7/8” K.O. OPTIONAL RETURN AIR CUT-OUT (either side) FOR USE WITH EXTERNAL FILTER FRAME 23-3/4 30-1/8 LEFT SIDE DIMENSIONS Models PV9A12N040UP11 1200 PV9B12N060UP11...
  • Page 3: High Altitude Pressure Switch Application

    HIGH ALTITUDE PRESSURE SWITCH APPLICATION Models PV9A12N040UP11 PV9B12N060UP11 PV9B12N080UP11 PV9C16N080UP11 PV9C20N100UP11 PV9D20N120UP11 NOTE: For high altitude conversion, an orifice change may also be required. See Form 035-14447-001 for application information. ELECTRICAL AND PERFORMANCE DATA Input Output Nominal High/Low High/Low Models PV9A12N040UP11 40/26 38/24...
  • Page 4: Air Flow Data

    036-21584-001 Rev. B (1004) AIR FLOW DATA 40,000 INPUT - 3 Ton m³/min High High 1340 38.0 1205 34.1 1255 35.6 1150 32.6 1170 33.2 1025 29.0 1045 29.6 23.7 26.9 22.2 24.5 20.5 80,000 INPUT - 3 Ton m³/min High High 1310...
  • Page 5: Filter Performance - Pressure Drop Inches W.c. And (Kpa)

    BLK (HOT) WHT (NEUTRAL) LINE WIRING CONNECTIONS ROOM FURNACE THERMOSTAT CONTROL TO AIR CONDITIONER W1/W CONTROLS Y/Y2 COMMON T’STAT CONNECTION TWO-STAGE HEATING AND TWO-STAGE COOLING THERMOSTAT CONNECTIONS FILTER PERFORMANCE The airflow capacity data published in the “Blower Perfor- mance” table listed above represents blower performance WITHOUT filters.
  • Page 6: Concentric Vent Termination

    036-21584-001 Rev. B (1004) ACCESSORIES PROPANE (LP) CONVERSION KIT - 1NP0580 - All units This accessory conversion kit may be used to convert natural gas (N) units for propane (LP) operation. Conversions must be made by qualified distributor or dealer personnel. CONCENTRIC VENT TERMINATION - 1CT0302 (2") 1CT0303 (3")