TECHNICAL GUIDE
AFFINITY
MODELS: PT9
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
DOWNFLOW/HORIZONTAL
TWO STAGE FURNACES
NATURAL GAS
60 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
ISO 9001
Certified Quality
Management System
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on commercial applications.
5-year limited parts warranty.
FEATURES
• Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
• Provides increased comfort level & very quiet unit opera-
tion.
• Adjustable delay timer allows two stage operation with sin-
gle stage thermostat.
• Compact, easy to install, ideal height 40" cabinet.
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-
tion.
• Integrated control module for reliable, economical opera-
tion.
• May be installed as either two-pipe (sealed combustion) or
single pipe vent (using indoor combustion air).
• Top intake & vent connection allows installation in narrow
locations.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• Induced combustion system with inshot main burners for
quiet, efficient operation.
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• PSC - four speed, direct drive motor with large, quiet
blower.
• 24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-
grade stainless steel.
• Timed on, adjustable off blower capability for maximum
comfort.
• Independent door removal for greater durabilty and ease
of access.
• Easy access from front of unit for cleaning, maintenance or
service.
• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
• 3-way transition facilitates fresh air piping.
246782-YTG-B-0407

Advertisement

Table of Contents
loading

Summary of Contents for York AFFINITY PT9

  • Page 1 CERTIFIED Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.york.com for the most up-to-date technical information. Additional rating information can be found at www.gamanet.org. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE...
  • Page 2: Cabinet And Duct Dimensions

    246782-YTG-B-0407 22-3/4 13-7/8 HORIZONTAL CONDENSATE DRAIN OPENING 2” JUNCTION BOX HOLE 7/8” GAS PIPE ENTRY 1-1/2” CONDENSATE DRAIN HOLE 7/8” SIDE PIPING HOLE 3-3/8” 2-1/4 22-1/4 25-3/8 26-1/2 27-1/8 30-1/8 LEFT SIDE 1-1/4 CABINET AND DUCT DIMENSIONS Models PT9B12N060DH11 1200 PT9B12N080DH11 1200 PT9C16N080DH11...
  • Page 3: Blower Performance Cfm

    BLOWER PERFORMANCE CFM Speed Models High Medium High PT9B12N060DH11 Medium Low High Medium High PT9B12N080DH11 Medium Low High Medium High PT9C16N080DH11 Medium Low High Medium High PT9C20N100DH11 Medium Low High Medium High PT9D20N120DH11 Medium Low NOTES: 1. Airflow expressed in standard cubic feet per minute. 2.
  • Page 4: Recommended Filter Sizes

    246782-YTG-B-0407 FILTER PERFORMANCE The airflow capacity data published in the “Blower Perfor- mance” table listed above represents blower performance WITHOUT filters. To determine the approximate blower per- formance of the system, apply the filter drop value for the fil- ter being used or select an appropriate value from the “Filter Performance”...
  • Page 5 246782-YTG-B-0407 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalog Section. Thermostat Chart - AC Unitary Products Group...
  • Page 6 246782-YTG-B-0407 Thermostat Chart - HP Unitary Products Group...
  • Page 7: Concentric Vent Termination

    ACCESSORIES PROPANE (LP) CONVERSION KIT - 1NP0347 - All units This accessory conversion kit may be used to convert natural gas units for propane (LP) operation. Conversions must be made by qualified distributor or dealer personnel. CONCENTRIC VENT TERMINATION - 1CT0302 (2") 1CT0303 (3") For use through rooftop, sidewall.
  • Page 8 Subject to change without notice. Printed in U.S.A. Copyright © by York International Corp. 2007. All rights reserved. Unitary Products Group Supersedes: 246782/035-21633-002 Rev. A (1205) 5005 York Drive 246782-YTG-B-0407 Norman 73069...

This manual is also suitable for:

Pt9b12n060dh11Pt9b12n080dh11Pt9c16n080dh11Pt9c20n100dh11Pt9d20n120dh11

Table of Contents