Electrical Power; Nominal Manifold Pressure; Electrical And Performance Data - York GF9S*DH Installation Manual

High efficiency tubular heat exchanger series 40 - 120 mbh input (11.72 - 35.17 kw) input
Table of Contents

Advertisement

268890-UIM-B-0607
TABLE 6: Nominal Manifold Pressure
Manifold Pressures (in wc)
800
850
900
950
1000
1050
1100
2500 (LP)
PROPANE AND HIGH ALTITUDE CONVERSION KITS
It is very important to choose the correct kit and/or gas orifices for the altitude and the type of gas for which the furnace is being installed.
Only use natural gas in furnaces designed for natural gas. Only use propane (LP) gas for furnaces that have been properly converted to use pro-
pane (LP) gas. Do not use this furnace with butane gas.
Incorrect gas orifices or a furnace that has been improperly converted will create an extremely dangerous condition resulting in premature heat
exchanger failure, excessive sooting, high levels of carbon monoxide, personal injury, property damage, a fire hazard and/or death.
High altitude and propane (LP) conversions are required in order for the appliance to satisfactory meet the application.
An authorized distributor or dealer must make all gas conversions.
In Canada, a certified conversion station or other qualified agency, using factory specified and/or approved parts, must perform the conversion.
The installer must take every precaution to insure that the furnace has been converted to the proper gas orifice size when the furnace is installed.
Do not attempt to drill out any orifices to obtain the proper orifice size. Drilling out a gas orifice will cause misalignment of the burner flames,
causing premature heat exchanger burnout, high levels of carbon monoxide, excessive sooting, a fire hazard, personal injury, property damage
and/or death.
SECTION V: ELECTRICAL POWER
ELECTRICAL POWER CONNECTIONS
Field wiring to the unit must be grounded. Electric wires that are field
installed shall conform to the temperature limitation for 63°F (35°C) rise
wire when installed in accordance with instructions. Refer to Table 7 in
these instructions for specific furnace electrical data.
TABLE 7: Electrical and Performance Data
Input/Cabinet
Output
MBH
kW
MBH
40/A
12
37
60/B
18
55
80/B
23
74
80/C
23
74
100/C
29
93
100/C
29
93
120/D
35
112
Max. Outlet
Input/Cabinet
Air Temp.
MBH
kW
°F
40/A
12
165
60/B
18
165
80/B
23
165
80/C
23
165
100/C
29
165
100/C
29
165
120/D
35
165
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
NOTES:
1. For altitudes above 2000 ft. (609 m) reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 140° F (60°C), 3% voltage drop.
3. Continuous return air temperature must not be below 55°F (12.8° C).
10
Altitude (feet)
0-7999
8000-8999
9000-9999
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.2
3.5
2.9
3.2
2.7
9.8
8.2
Nominal Airflow
3
kW
CFM
m
/min
10.8
1200
34
16.1
1200
34.0
21.7
1200
34.0
21.7
1600
45.3
27.3
1600
45.3
27.3
2000
56.6
32.8
2000
56.6
Blower
°C
HP
Amps
73.9
1/2
7.0
73.9
1/2
7.0
73.9
1/2
7.0
73.9
3/4
10.2
73.9
3/4
10.2
73.9
1
12.7
73.9
1
12.7
3.5
29.8
3.5
31.7
3.5
33.5
3.3
35.4
2.9
37.3
2.7
39.1
2.4
41.0
7.5
93.2 (LP)
Use copper conductors only.
Cabinet Width
Total Unit
In.
mm
Amps
14-1/2
368
17-1/2
444
17-1/2
444
21
533
21
533
21
533
24-1/2
622
Max.
Blower Size
Over-current
Protect
In.
cm
11 x 8
27.9 x 20.3
11 x 8
27.9 x 20.3
11 x 8
27.9 x 20.3
11 x 10
27.9 x 25.4
11 x 10
25.4 x 25.4
11 x 11
27.9 x 27.9
11 x 11
27.9 x 27.9
Manifold Pressures (kpa)
Altitude (m)
0-2437
2438-2742
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.87
0.80
0.87
0.73
0.80
0.66
2.44
2.03
AFUE
%
9
94
35 - 65
9
92
35 - 65
9
92
35 - 65
12
92
35 - 65
12
92
35 - 65
14
92
35 - 65
14
92
35 - 65
Min. Wire Size
(awg) @ 75 ft.
One Way
Lbs.
20
14
20
14
20
14
20
14
20
14
20
12
20
12
Unitary Products Group
2743-3048
0.87
0.87
0.87
0.81
0.73
0.67
0.61
1.86
Air Temp. Rise
°F
°C
19 - 36
19 - 36
19 - 36
19 - 36
19 - 36
19 - 36
19 - 36
Operation
Weight
Kg.
120
54.5
130
59.0
145
65.9
155
70.5
170
77.3
175
79.5
180
81.8