COOLING CAPACITY - COIL ONLY
Model Coil
Rated CFM
G2FD024(S,H)14(T)
G2FD024(S,H)17(T)
G2FD030(S,H)17(T)
G2FD035(S,H)14(T)
G2FD036(S,H)17(T)
G2FD036(S,H)21(T)
G2FD046(S,H)17(T)
G2FD042(S,H)21(T)
G2FD048(S,H)21(T)
G2FD048(S,H)24(T)
G2FD060(S,H)24(T)
G2FD061(S,H)24(T)
*
See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity.
(T) indicates models with factory installed thermal expansion valve. Only available on coils with factory installed horizontal drain pan (H).
Notes:
• G2FD coils available with a factory installed horizontal drain pan option (H).
• G2FD061H24 is only available with a factory mounted horizontal pan.
COOLING CAPACITY - COIL ONLY
RATED
MODEL
CFM
G1HA024H14(T)
800
G1HA036H14(T)
1150
G1HA036H17(T)
1200
G1HA048H21(T)
1550
G1HA060H24(T)
1800
*
See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity.
(T) indicates models with factory installed thermal expansion valve.
Unitary Products Group
*
Entering Air °F
(Wet Bulb)
FULL-CASED "A" TYPE MULTI-POSITION
72
67
850
62
57
72
67
1025
62
57
72
67
1250
62
57
72
67
1200
62
57
72
67
1400
62
57
72
67
1650
62
57
72
67
1825
62
57
72
67
2000
62
57
*
ENTERING AIR
°F
(WET BULB)
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
72
67
62
57
MBH@ Evaporator Temperature and Corresponding Pressure °F / PSIG
35 / 61.5
40 / 68.5
36.3
33.0
33.4
30.2
27.4
24.3
22.2
19.3
41.5
37.8
36.2
32.4
29.1
25.3
24.1
21.5
52.0
47.3
41.7
36.8
32.5
27.3
27.9
25.8
53.4
48.6
42.8
37.8
33.4
28.1
28.7
26.5
88.4
76.0
70.8
59.4
55.2
43.9
47.4
41.5
100.5
86.4
80.4
67.5
62.7
49.9
53.9
47.2
119.9
101.0
96.0
79.2
74.8
58.6
64.3
55.4
124.8
105.2
99.9
82.5
77.9
61.1
66.9
57.7
MBH @ EVAPORATOR TEMPERATURE AND
CORRESPONDING PRESSURE °F / PSIG
35/61.5
40/68.5
35.2
32.0
32.4
29.3
26.6
23.6
21.5
18.7
49.1
44.7
39.4
34.8
30.7
25.9
26.4
24.4
73.4
63.1
58.8
49.3
45.8
36.4
39.3
34.4
94.4
81.2
75.6
65.4
59.0
46.9
50.6
44.4
112.8
95.0
90.3
74.5
70.3
55.1
60.4
52.1
036-21145-003 Rev. A (0403)
45 / 76.0
50 / 84.0
29.5
25.6
26.7
23.1
21.0
17.7
16.2
12.6
33.7
29.5
28.6
24.5
24.0
19.2
18.7
15.8
42.3
37.3
32.3
27.4
29.8
22.2
23.8
22.2
43.4
38.3
33.1
28.2
30.6
22.8
24.5
22.8
63.3
50.0
48.4
37.0
35.8
29.9
35.8
29.9
72.0
56.8
55.0
42.1
40.7
34.0
40.7
34.0
80.0
62.2
62.6
45.8
46.2
37.0
46.2
37.0
85.3
64.7
65.2
47.7
48.1
38.6
48.1
38.6
45/76.0
50/84.0
28.6
24.8
25.9
22.4
20.4
17.2
15.7
12.2
39.9
35.2
30.5
25.9
28.2
22.8
22.5
21.0
52.5
41.5
40.2
30.7
29.7
24.8
28.1
23.2
67.6
53.4
51.7
39.5
38.2
32.0
35.6
29.7
77.0
58.4
58.8
43.1
43.4
34.9
40.4
31.9