Cooling Capacities - Models - York D1HE/D1HG036 Technical Manual

Sunline ultra single package air-cooled air conditioners 3, 4 and 5 nominal ton 12.2 through 13.2 seer
Table of Contents

Advertisement

TABLE 6: COOLING CAPACITIES - MODELS DHE/DHG 036 -
AIR ON
EVAPORATOR
COIL
WB
CFM
°F
1500
72
47.6
67
42.5
62
38.0
57
37.4
1350
72
46.5
67
41.6
62
37.1
57
36.5
1200
72
45.4
67
40.6
62
36.2
57
35.7
1050
72
43.2
67
38.7
62
34.5
57
34.0
900
72
41.1
67
36.7
62
32.8
57
32.3
AIR ON
EVAPORATOR
COIL
WB
CFM
°F
1500
72
43.6
67
39.3
62
34.8
57
34.9
1350
72
42.9
67
38.6
62
34.2
57
34.3
1200
72
42.2
67
37.9
62
33.6
57
33.7
1050
72
40.1
67
36.1
62
32.0
57
32.1
900
72
38.0
67
34.2
62
30.3
57
30.4
1.
These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance
Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit
2.
These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor
power input is 0.36kW. Refer to Tables 10 and 11 for the kW of the supply air blower motor.
3.
These capacities are gross ratings. For net capacity, determine the kW of the supply air blower from Tables 10 and 11, multiply this value
by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.
NOMINAL RATING
8
TEMPERATURE OF AIR ON CONDENSER COIL
TOTAL
POWER
1
CAP.
2
INPUT
MBH
86
3.65
32.3
3.56
39.0
3.49
38.0
3.54
37.4
3.62
29.7
3.53
36.0
3.46
37.1
3.52
36.5
3.60
27.2
3.51
33.0
3.44
36.2
3.49
35.7
3.57
24.6
3.48
29.9
3.41
33.9
3.47
34.0
3.54
22.0
3.45
26.8
3.39
31.5
3.44
32.3
TEMPERATURE OF AIR ON CONDENSER COIL
TOTAL
POWER
CAP.
INPUT
MBH
86
3.85
30.4
3.76
37.8
3.67
34.8
3.73
34.9
3.83
28.0
3.74
34.8
3.66
34.2
3.72
34.3
3.82
25.5
3.73
31.8
3.64
33.6
3.70
33.7
3.78
22.9
3.69
28.7
3.61
31.6
3.67
32.1
3.75
20.4
3.66
25.6
3.58
29.5
3.64
30.4
105°F - 115ºF
105°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
83
80
77
27.8
23.3
18.9
14.4
34.5
30.0
25.6
21.1
38.0
36.6
32.1
27.6
37.4
37.4
32.9
28.5
25.8
21.8
17.8
13.8
32.0
28.0
24.0
20.1
36.6
34.1
30.1
26.1
36.5
35.2
31.2
27.2
23.7
20.2
16.7
12.2
29.5
26.0
22.5
19.0
35.2
31.7
28.2
24.7
35.7
33.0
29.5
26.0
21.6
18.5
12.5
26.9
23.8
20.8
17.8
32.1
29.0
26.0
23.0
32.9
30.3
27.2
24.2
19.4
16.8
14.3
11.7
24.2
21.7
19.1
16.5
28.9
26.4
23.8
21.2
30.1
27.5
24.9
22.4
115°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
83
80
77
26.0
21.5
17.0
12.5
33.3
28.8
24.3
19.9
34.8
34.4
29.9
25.4
34.9
34.9
30.5
26.0
24.0
20.0
16.0
12.0
30.8
26.8
22.8
18.8
34.0
32.0
28.0
24.0
34.3
32.9
28.9
24.9
22.0
18.5
15.0
11.5
28.3
24.8
21.3
17.8
33.1
29.6
26.1
22.6
33.7
30.9
27.4
23.9
19.9
16.9
13.8
10.8
25.7
22.6
19.6
16.6
30.0
27.0
23.9
20.9
30.9
28.2
25.1
22.1
17.8
15.2
12.7
10.1
23.0
20.4
17.9
15.3
26.9
24.4
21.8
19.2
28.0
25.4
22.9
20.3
ALL SENSIBLE CAPACITY
036-21216-003-A-0204
3
74
71
68
#N/A
#N/A
16.6
12.1
23.1
18.7
24.0
19.5
#N/A
#N/A
16.1
12.1
22.2
18.2
23.3
19.3
#N/A
#N/A
15.5
12.0
21.2
17.7
22.5
19.0
#N/A
#N/A
14.7
11.7
19.9
16.9
21.2
18.1
#N/A
#N/A
14.0
11.4
18.7
16.1
19.8
17.2
74
71
68
#N/A
#N/A
15.4
10.9
20.9
16.5
21.5
17.0
#N/A
#N/A
14.9
10.9
20.0
16.0
21.0
17.0
#N/A
#N/A
14.3
10.8
19.1
15.6
20.4
16.9
#N/A
#N/A
13.5
10.5
17.9
14.9
19.1
16.0
#N/A
#N/A
12.7
10.2
16.7
14.1
17.7
15.2
Unitary Products Group

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents