Cooling Capacities - Models Dhe/Dhg060 - York D1HE/D1HG036 Technical Manual

Sunline ultra single package air-cooled air conditioners 3, 4 and 5 nominal ton 12.2 through 13.2 seer
Table of Contents

Advertisement

TABLE 8: COOLING CAPACITIES - MODELS DHE/DHG060
AIR ON
EVAPORATOR
COIL
TOTAL
POWER
1
CAP.
INPUT
WB
MBH
CFM
°F
72
82
67
70
2500
62
67
57
66
72
78
67
67
2250
62
64
57
63
72
75
67
64
2000
62
61
57
60
72
72
67
62
1750
62
59
57
58
72
69
67
59
1500
62
56
57
55
AIR ON
EVAPORATOR
COIL
TOTAL
POWER
1
CAP.
INPUT
WB
MBH
CFM
°F
72
68
67
60
2500
62
56
57
55
72
67
67
58
2250
62
55
57
54
72
65
67
57
2000
62
53
57
52
72
62
67
54
1750
62
51
57
50
72
59
67
52
1500
62
48
57
47
1.
These capacities are gross ratings. For net capacity, determine the KW of the supply air blower motor from the Blower Performance
Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit
2.
These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan
motor power input is 0.36kW. Refer to Tables 10 and 11 for the kW of the supply air blower motor.
3.
These capacities are gross ratings. For net capacity, determine the kW of the supply air blower from Tables 10 and 11, multiply
this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit.
NOMINAL RATING
10
TEMPERATURE OF AIR ON CONDENSER COIL
85°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
4.3
56
50
43
37
4.2
67
61
54
48
4.0
67
67
66
59
4.0
66
66
66
59
4.3
53
47
41
35
4.2
63
57
51
45
4.0
64
64
62
56
4.0
63
63
63
57
4.3
49
43
38
33
4.2
58
53
48
42
4.0
61
61
58
52
4.0
60
60
59
54
4.3
44
40
35
30
4.2
53
49
44
39
4.0
59
57
53
48
4.0
58
57
55
50
4.2
40
36
32
28
4.1
48
44
40
36
4.0
56
53
49
44
4.0
55
54
50
46
TEMPERATURE OF AIR ON CONDENSER COIL
105°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
5.0
51
44
38
31
4.8
60
55
49
42
4.8
56
56
56
49
4.7
55
55
55
48
4.9
48
42
36
30
4.8
57
52
46
40
4.7
55
55
54
48
4.7
54
54
53
47
4.9
44
39
33
28
4.8
54
48
43
38
4.7
53
53
52
46
4.7
52
52
52
46
4.9
40
35
31
26
4.8
49
44
40
35
4.7
51
50
48
43
4.6
50
50
48
43
4.9
36
32
28
24
4.7
44
40
36
32
4.7
48
47
43
39
4.6
47
47
43
39
3
TOTAL
POWER
1
CAP.
INPUT
MBH
74
71
68
30
-
-
76
4.6
41
34
28
65
4.5
52
46
39
62
4.5
52
46
39
61
4.4
29
-
-
73
4.6
39
33
27
62
4.5
50
44
38
60
4.4
51
45
39
58
4.4
27
-
-
70
4.6
37
32
26
60
4.5
47
42
36
57
4.4
49
43
38
56
4.4
25
-
-
67
4.6
34
30
25
58
4.5
44
39
34
55
4.4
45
40
36
54
4.4
24
-
-
65
4.6
32
28
23
56
4.5
40
36
32
53
4.4
42
37
33
52
4.4
3
TOTAL
POWER
1
CAP.
INPUT
MBH
74
71
68
25
-
-
61
5.3
35
29
22
55
5.1
43
36
29
50
5.1
42
35
28
49
5.0
24
-
-
60
5.3
34
28
22
54
5.1
42
36
30
49
5.0
41
35
29
49
5.0
23
-
-
60
5.2
32
27
22
54
5.1
41
36
30
49
5.0
41
36
30
48
5.0
21
-
-
56
5.2
30
25
21
51
5.0
38
33
29
46
5.0
38
33
29
46
4.9
20
-
-
53
5.2
28
24
20
48
5.0
35
31
27
43
4.9
35
31
27
43
4.9
ALL SENSIBLE CAPACITY
036-21216-003-A-0204
95°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
74
54
48
41
34
28
65
58
51
45
38
62
62
62
55
49
61
61
61
54
47
50
44
38
32
26
60
54
48
42
36
60
60
59
53
47
58
58
58
52
46
46
41
36
30
25
56
50
45
39
34
57
57
55
50
45
56
56
56
50
45
43
38
33
28
24
51
46
41
37
32
55
54
51
46
42
54
54
51
47
42
39
34
30
26
22
46
42
38
34
30
53
51
47
43
39
52
51
47
43
39
115°F
SENSIBLE CAPACITY
ENTERING DRY BULB, °F
2
86
83
80
77
74
48
41
35
28
21
55
53
46
39
33
50
50
50
43
37
49
49
49
43
36
45
39
33
27
21
53
50
44
38
32
49
49
49
43
37
49
49
49
43
37
42
36
31
26
20
52
47
41
36
30
49
49
48
43
37
48
48
48
42
37
38
33
28
24
19
47
42
38
33
28
46
46
44
39
34
46
46
44
39
34
34
30
26
22
18
43
38
34
30
26
43
43
40
36
32
43
43
40
36
31
Unitary Products Group
3
71
68
-
-
31
25
42
35
41
34
-
-
30
24
41
35
40
34
-
-
29
23
39
34
39
34
-
-
27
22
37
32
37
32
-
-
26
21
35
30
35
30
3
71
68
-
-
26
20
30
23
29
23
-
-
26
20
31
25
31
25
-
-
25
20
32
26
32
26
-
-
23
19
30
25
29
25
-
-
22
18
27
23
27
23