Lighting Instructions - Graco ThermoLazer 258699 Operation

Pavement marking system
Hide thumbs Also See for ThermoLazer 258699:
Table of Contents

Advertisement

Lighting Instructions

Lighting Instructions
Lighting Kettle Burners
Read For Your Safety, page 7.
1. Turn temperature control knob (AA) to 0 ("OFF").
AA
ti14124a
2. Turn kettle gas safety valve (CC) to "OFF".
ti14131a
3. Open burner view port.
4. Open manual shut-off valve on propane tank
located at front of unit; open kettle manual shut-off
valve (KK) below kettle and behind propane tank.
ti14127a
5. Turn gas safety valve (CC) to "PILOT".
DD
ti14131a
10
CC
ti14130a
ti14129a
CC
6. Push in gas safety valve knob.
7. Push kettle pilot burner igniter (DD) until pilot
ignites.
8. Continue to push in gas safety valve (CC) in for
approximately 1 minute. If pilot goes out, repeat
steps 4-6 after 10 minutes.
If pilot ignites without depressing the gas safety valve
knob, replace gas safety valve. If gas safety valve
knob does not pop back after releasing in pilot posi-
tion, STOP and replace gas safety valve. Shut off gas
at propane tank before replacing valve.
9. Turn gas safety valve knob to "ON".
10. Turn temperature to 250° F (121° C) and observe
that main burners have ignited. Turn kettle tempera-
ture control back to "0" and observe that main burn-
ers shut off.
If main burners do not ignite or shut off when rotating
temperature control knob, STOP. Shut off gas at the
propane tank. Follow diagnostic procedure in Repair
manual.
11. Close burner view port.
12. Turn temperature control to desired setting.
Shutting Off Burner
1. Turn gas safety valve to "OFF".
2. Close manual shut-off valve on propane tank. Close
kettle manual shut-off valve (KK) when finished
KK
heating with kettle burners.
ti14128a
NOTE: The kettle gas burner can be lit manually with a
small torch (for example: DOT 39 NRC 228/286 Cylinder
with #3 torch tip) if the battery powered pulse ignitor fails
to light the pilot.
KK
ti14125a
313787C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thermolazer 257500

Table of Contents