Preparing ThermoLazer
for Application
Preparing ThermoLazer
Keep all access covers closed and latched when equip-
ment is in use.
Always secure ThermoLazer
when adding thermoplastic.
1. Make sure kettle burners and SmartDie
box burner are lit.
2. Allow kettle to heat up before adding material. If ket-
tle is completely empty, allow kettle to reach
300° - 350° F (149° - 177° C) before adding mate-
rial. If kettle has material, allow material to reach
380° F (193° C) before adding material.
3. Secure ThermoLazer
4. Add thermoplastic material to kettle.
16
by chocking wheels
screed
by chocking wheels.
ti14603a
ti14122a
for Application
5. Move ControlFlow
raised position and fill screed box with melted ther-
moplastic material.
S
NOTE: The material gate is adjustable. The gate is
factory set at a 0.5 in. (1.3 cm) gap. You can
increase this gap for more material flow or decrease
the gap for less material flow.
6. Do not overfill material in kettle. Overfill would be
material higher than 5 in. (13 cm) below top of ket-
tle.
Overfill
Line
7. Close and latch cover access doors when applying
thermoplastic.
8. Avoid bumping or impacting Thermolazer
vent spillage or splashing of hot material.
Gate Valve Actuator (S) to
ti14123a
ti14410a
0.5 in.
5.0 in.
to pre-
313787C