Application Programs

Soft Key Functions
Start
Start application program
Weigh.
Toggle to basic weighing
functions
Using Verified Balances as Legal
Measuring Instruments in the EU*:
All application programs can be selected
on balances verified for use in legal
metrology.
Calculated values can be indicated as
follows:
– Percent
– Piece counting (Counting) = pcs
– Computed value
Auto-Start Application When the
Power Goes On
In the Setup menu, you can select
whether the last application active
before you turn off the power starts
automatically when the power is turned
on again (Setup: Application para-
meters: Auto-start app. when power
goes on: On)
Toggle between Two Weight
Units
( )
Purpose
With this application program you can
switch the display of a weight value
back and forth between two weight
units by pressing a soft key.
You can use the "Toggle between Two
Weight Units" application in combination
with a program chosen from Application
2 (checkweighing, time-controlled
functions) and one from Application 3
(totalizing, formulation, statistics) as
well as with the extra functions.
Available Features
– Toggling the displayed weight
– Setting the display accuracy
– Other features as for the basic weighing
function
Factory Settings
Grams /g
Weight unit 1:
All digits
Display accuracy 1:
Grams /g
Weight unit 2:
All digits
Display accuracy 2:
* including the Signatories of the Agree-
ment on the European Economic Area
Preparation
Balances used as legal measuring instruments: grams and kilograms are the only weight
units available
Standard balances: The following weight units are available in both ranges:
Unit
Grams
Kilograms
Carats
Pounds
Ounces
Troy ounces
= %
Hong Kong taels
Singapore taels
Taiwanese taels
= o,G
Grains
Pennyweights
Milligrams
Parts per pound
Chinese taels
Mommes
Austrian carats
Tola
Baht
Mesghal
Turn on the balance: Press e
Select the Toggle Weight Units application in the Setup menu: press o
Application parameters
Select
then the
O
Application 1 (basic settings)
Toggle wt. units
Select
Toggle wt. units
Confirm
Toggle wt. units
ο = factory setting
* = not for verified balances used as legal measuring instruments
see also "Application Parameters (Overview)" in the chapter entitled "Configuration"
Save settings and exit the Setup menu: press the
Conversion factor
1.00000000000
0.00100000000
5.00000000000
0.00220462260
0.03527396200
0.03215074700
0.02671725000
0.02645544638
0.02666666000
15.43235835000
0.64301493100
1000.00000000000
1.12876677120
0.02645547175
0.26670000000
5.00000000000
0.08573333810
0.06578947437
0.21700000000
soft key once
: (repeatedly) press the
: press the
Weight unit 1
Display accuracy 1
Weight unit 2
Display accuracy 2
Display/
Line for
Printout
metrological data
g
g
kg
kg
ct
ct
lb
lb
oz
oz
ozt
ozt
tlh
tlh
tls
tls
tlt
tlt
GN
GN
dwt
dwt
mg
mg
/lb
lb
tlc
tlc
mom
M
K
K
tol
tol
bat
bat
MS
MS
soft key 2 +,
: press the
q
: press the
soft key
O
or
soft key
Q
q
O
soft key
see above
ο All digits
Reduced by 1 digit for weight change
Reduced by 1 digit *
see above
ο All digits
Reduced by 1 digit for weight change
Reduced by 1 digit *
soft key
oo
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents