Specifications - SMC Networks D 7K Series Manual

Trimmer auto switch
Hide thumbs Also See for D 7K Series:

Advertisement

Direct mounting
(Round groove)
Specifi cations
Sensor Unit
Auto switch model
D-M9K
D-M9K
Mounting
Direct mounting (Round groove) Direct mounting (Square groove) Rail mounting
Applicable amplifi er unit
Indicator lamp Red lights ON at sensitive position. Green lights ON at optimum detecting position.
Electrical entry
Impact resistance
Insulation resistance 50 MΩ or more (500 VDC measured via megohmmeter) between lead wire and case
Withstand voltage 1000 VAC for 1 minute (between lead wire and case)
Ambient temperature
Enclosure
Weight (with connector)
55 g
Standard
Oilproof Heavy-duty Cable
D-M9K
Auto switch model
Sheath
Outside diameter [mm]
Number of cores
Insulator
Outside diameter [mm]
2
Effective area [mm
]
Conductor
Strand diameter [mm]
Minimum bending radius [mm] (Reference value)
Connector for sensor
(e-con connector)
Note) The connector for sensor (e-con connector) is not attached to the lead wire.
It will be supplied loose in the same shipment (1 pc.).
Internal Circuit
Sensor Unit
D-M9K/D- 7K
Trimmer Auto Switch
D-M9K/D- 7K/D-R K
Direct mounting
(Square groove)
D-Y7K
D-Y7K
D-F7K
D-F7K
D-RNK, D-RPK
Grommet
2
980 m/s
−10 to 60°C
IP67
58 g
CE Marking
D-Y7K
D-F7K
ø3.5
4 cores (Brown/Blue/Black/White)
ø1.0
0.15 (AWG26)
ø0.08
21
Vsw
Brown
GND
Blue
SOUT1
Black
SOUT2
White
Rail mounting
A
Amplifier Unit (with S
Amplifi er Unit (with Sensor Unit)
lifi U it (
Model
Applicable sensor unit
Application
Power supply voltage
Current consumption
Output specifi cation NPN open collector 2 outputs PNP open collector 2 outputs
Load voltage
Load current
Internal voltage drop
Leakage current
Response time
READY: Red lights ON when the piston
Indicator lamp
OUT1: Green lights ON when turned ON.
OUT2: Orange lights ON when turned ON.
Connection to sensor
Electrical
entry
Power supply/output cable
Impact resistance
Insulation resistance 50 MΩ or more (500 VDC measured via megohmmeter) between lead wire and case
Withstand voltage 1000 VAC for 1 minute (between lead wire and case)
Ambient temperature
Enclosure
Weight
Standard
Oilproof Heavy-duty Cable
Model
Sheath
Outside diameter [mm]
Number of cores
Insulator
Outside diameter [mm]
Effective area [mm
Conductor
Strand diameter [mm]
Minimum bending radius [mm] (Reference value)
Amplifi er Unit
D-RNK
OUT1
OUT2
4: Vsw
Brown
3: SOUT2
Main circuit
White
2: GND
of switch
Blue
1: SOUT1
Black
D-RPK
OUT1
OUT2
4: Vsw
Brown
3: SOUT2
Main circuit
White
2: GND
of switch
Blue
1: SOUT1
Black
RoHS
U it)
PLC: Programmable Logic Controller
PLC: Programmable Logic Controller
D-RNK
D-RPK
D-M9K, D-Y7K, D-F7K
For relay and PLC
12 to 24 VDC
40 mA or less
28 VDC or less
80 mA or less/1 output
1.5 V or less
100 μA or less/1 output
1 ms or less
position detected (with sensor unit).
e-con connector
Grommet
2
98 m/s
−10 to 60°C
IP40
70 g
CE Marking
D-RNK
D-RPK
ø3.5
4 cores (Brown/Blue/Black/White)
ø1.0
2
]
0.15 (AWG26)
ø0.08
21
READY
DC (+)
+
Brown
12 to 24 VDC
OUT1
Black
OUT2
White
DC (−)
Blue
READY
DC (+)
+
Brown
12 to 24 VDC
OUT1
Black
OUT2
White
DC (−)
Blue
2