EB-E01 series
3.5.1.2 Ground continuity check
Testing apparatus
Multimeter (with sensitivity down to 0.1 Ω)
Measurement range: Select "Ω"
Tester lead wires:
• Black lead wire: Connect it to the "COM" terminal.
• Red lead wire: Connect it to the "V/Ω/Hz" terminal.
Standard/Judgment level
Should be no resistance (0.5 Ω or less)
SEIKO EPSON
Disassembly and Assembly
Testing procedure
1. Turn the tester on.
2. Check that the resistance between "C" of the Computer terminal and
"G" of the AC inlet of the projector (1) is 0.5 Ω or less.
Measure EH-TW740 at the position in the figure below.
3.5.1.3 Illumination check
Test conditions
Input a PC or video signal and check the illumination for about 5 minutes.
1. Judgment
Projector should operate normally with no smoke or fire.
144
INTERNAL USE ONLY
1
Revision A