3-2-2 General-purpose input (DI0 to DI7)

These general-purpose inputs are available to users for handling data input in a program.
These inputs are usually connected to sensors or switches. These inputs can also be directly con-
nected to a PLC output circuit.
As a special function during execution of an ABS-PT or INC-PT point movement command, these
general- purpose inputs can be used to specify the point numbers and movement speed.
The number of general-purpose input (DI) points used to specify the point numbers and speed differs
depending on whether SERVICE mode is enabled or disabled and also on the PRM7 (I/O point
movement command speed parameter) setting.
For example, when PRM7 is 100 in normal mode (SERVICE mode disabled), the point numbers
should be input in binary code with DI0 to DI7 to specify P0 to P255 as shown in the table below.
If PRM7 is 0 in normal mode (SERVICE mode disabled), then point numbers should be input with
DI0 to DI5 in binary code to specify P0 to P63 as shown in the table below. The movement speed is
specified as 100% when both DI6 and DI7 are off. In other cases, it is set to the speed specified by the
parameter. (See "5-2 Parameter Description".) Also see the tables below for more details.
100 (default setting)
NORMAL mode
(SERVICE mode disabled)
100 (default setting)
SERVICE mode enabled
Example of point number setting
DI No.
DI7
DI6
7
6
Point No.
(2
)
(2
)
P0
OFF
OFF
P1
OFF
OFF
P3
OFF
OFF
P7
OFF
OFF
P15
OFF
OFF
P31
OFF
OFF
P63
OFF
OFF
P127
OFF
ON
P254
ON
ON
P255
ON
ON
Example of point movement speed setting
Speed setting pattern 1
DI7
DI6
Movement speed
OFF
OFF
100%
OFF
ON
PRM41
ON
OFF
PRM42
ON
ON
PRM43
Speed setting pattern 2
DI7
Movement speed
OFF
100%
ON
PRM7
Speed setting pattern 3
DI6
Movement speed
OFF
100%
ON
PRM7
* DI7 functions as the SERVICE mode input when the SERVICE mode function is enabled.
In this case, DI0 to DI6 can be used as the general-purpose inputs.
PRM7
DI used to specify point numbers
DI7 to DI0 (256 points)
1 to 99
DI6 to DI0 (128 points)
0
DI5 to DI0 (64 points)
DI6 to DI0 (128 points)
1 to 99
DI5 to DI0 (64 points)
DI5
DI4
DI3
DI2
5
4
3
2
(2
)
(2
)
(2
)
(2
)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
DI used to specify speed
Speed setting method
Not specified
100%
DI7
Speed setting pattern 2
DI7, DI6
Speed setting pattern 1
Not specified
100%
DI6
Speed setting pattern 3
DI1
DI0
1
0
(2
)
(2
)
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON

Advertisement

Table of Contents
loading

Table of Contents