Figure 20: 2-Foot Deco Grille And Protective Grille; Figure 21: Lower Clearance Shield; Figure 22: Venting - Roberts Gorden Vantage CTHN-40 Kit Instructions

Fuel conversion kit instructions
Hide thumbs Also See for Vantage CTHN-40:
Table of Contents

Advertisement

NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows.
2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream from
where the burner and burner tube connect.

FIGURE 20: 2-FOOT DECO GRILLE AND PROTECTIVE GRILLE

A
C
B
D

FIGURE 21: LOWER CLEARANCE SHIELD*

A
B
D
C
*When installed in the first 10' (3 m).

FIGURE 22: VENTING

A
E
Unvented
Radiant Tubes
Vented
Model
CTHN-40
CTHN-60
CTHN-80
CTHN-100
CTHN-125
CTHN-150
CTHN-175
CTHN-200
Model
CTHN-40
CTHN-60
CTHN-80
CTHN-100
CTHN-125
CTHN-150
CTHN-175
CTHN-200
Model
CTHN-40
CTHN-60
Vent
CTHN-80
Pipes
CTHN-100
CTHN-125
CTHN-150
F
CTHN-175
CTHN-200
(inches)
A
B
C
5
20
41
5
27
51
5
30
58
5
32
60
5
35
65
5
39
71
8
44
74
8
47
76
(inches)
A
B
C
5
25
22
5
30
27
5
37
37
5
39
39
5
41
41
5
43
50
- UNAPPROVED -
- UNAPPROVED -
(inches)
A
E
F
14
18
18
14
18
18
20
24
18
20
24
18
20
24
18
20
30
18
20
30
18
20
30
18
SECTION 6: C
RITICAL
(centimeters)
D
A
B
20
13
51
27
13
69
30
13
76
32
13
81
35
13
89
39
13
99
44
20
112
47
20
119
(centimeters)
D
A
B
25
13
64
30
13
76
37
13
94
39
13
99
41
13
104
43
13
109
- UNAPPROVED -
- UNAPPROVED -
(centimeters)
A
E
36
46
36
46
51
61
51
61
51
61
51
76
51
76
51
76
C
ONSIDERATIONS
C
D
104
51
130
69
147
76
152
81
165
89
180
99
188
112
193
119
C
D
56
64
69
76
94
94
99
99
104
104
127
109
F
46
46
46
46
46
46
46
46
17