Burner Conversion Label Information; Attach Burner Conversion Label; Figure 12: Label P/N 91039400 - Roberts Gorden Vantage CTHN-40 Kit Instructions

Fuel conversion kit instructions
Hide thumbs Also See for Vantage CTHN-40:
Table of Contents

Advertisement

FIGURE 12: Label P/N 91039400

Enter Data for Natural to Propane Conversions
Model
CTHN-40
CTHN-60
CTHN-80
CTHN-100
CTHN-125
CTHN-150
CTHN-175
CTHN-200
Step 5.7 Burner Conversion Label Information
Print the requested information in the fields of the
burner conversion label as shown in Figure 12.
Step 5.8 Attach Burner Conversion Label
1. Attach the small yellow gas label (included in
conversion kit) to the gas valve. Attach the
conversion label (P/N 91039400) to the burner
housing. See Page 8, Figure 6.
2. Replace all access doors and secure with
thumbscrews.
Propane Orifice Size
1.8 mm
#44
2.6 mm
#33
1/8"
3.4 mm
#27
#23
Enter Data for Propane to Natural Conversions
Model
Natural Orifice Size
CTHN-40
CTHN-60
CTHN-80
CTHN-100
CTHN-125
CTHN-150
CTHN-175
CTHN-200
SECTION 5: F
C
I
UEL
ONVERSION
NSTRUCTIONS
#33
#29
#21
#16
#9
#3
A
E
13